iXPeRiPheRaLMoDuLes7(usB):usBFunCtionContRoLLeR(usB)
iX-1-72
ePson
s1C33L17teChniCaLManuaL
0x300940:ePaControl(ePaControl)
name
address
Registername
Bit
setting
init. R/W
Remarks
D7
D6
D5
D4
D3
D2
D1
D0
0
R/W
R
W
R/W
0 when being read.
00300940
(B)
ePaControl
(ePacontrol)
autoForcenaK
enshortPkt
DisaF_naK_short
togglestat
toggleset
toggleClr
ForcenaK
ForcestaLL
Togglesequencebit
1 AutoforceNAK
0 Donothing
1 Enableshortpacket
0 Donothing
1 Disableautoforce
0 AutoforceNAKshort
1 Settogglesequencebit
0 Donothing
1 Cleartogglesequencebit
0 Donothing
1 ForceNAK
0 Donothing
1 ForceSTALL
0 Donothing
This register sets operations of the endpoint EPa.
D7
autoForcenaK
Sets the ForceNAK bit of this register to 1 when the transaction of the endpoint EPa completes
normally.
D6
enshortPkt
Setting this bit to 1 enables to send the data within the FIFO that is less than the quantity specified
for the MaxPacketSize, as a short packet for the IN transaction of the endpoint EPa. When the IN
transaction that transmitted short packets completes, this bit is automatically set to 0 (to be cleared).
When a packet of the max packet size is transmitted, this bit is not cleared.
If this bit is set to 1 when the FIFO has no data, a zero-length packet can be transmitted for the IN token
from the host. If the data is written into the FIFO that is in the transmission process with the packet to
which this bit is set, that data may be included in transmission. Therefore, do not write into the FIFO
until the packet transmission completes and this bit is cleared.
D5
DisaF_naK_short
When this bit is set to 0 (default setting) and the packet that was received at normal completion time of
the OUT transaction is a short packet, the ForceNAK bit is automatically set to 1. When this bit is set to
1, this function is disabled.
When the AutoForceNAK bit is set to 1, the AutoForceNAK bit has a priority.
D4
togglestat
Shows the status of the toggle sequence bit of the endpoint EPa.
D3
toggleset
Set the toggle sequence bit of the endpoint EPa to 1.
D2
toggleClr
Set the toggle sequence bit of the endpoint EPa to 0 (to be cleared).
D1
ForcenaK
If this bit is set to 1, the NAK response is done for the transaction of the endpoint EPa regardless of the
FIFO data quantity and space capacity.
When a transaction has been being done for a certain period of time, the setting of this bit will be
enabled from the next transaction.
D0
ForcestaLL
If this bit is set to 1, the STALL response is done for the transaction of the endpoint EPa. This bit has a
priority over the setting of the ForceNAK bit.
When a transaction has been being done for a certain period of time, the setting of this bit will be
enabled from the next transaction.