147
6.6
Idle Cycle
6.6.1
Operation
When the H8S/2214 accesses external space , it can insert a 1-state idle cycle (T
I) between bus
cycles in the following two cases: (1) when read accesses between different areas occur
consecutively, and (2) when a write cycle occurs immediately after a read cycle. By inserting an
idle cycle it is possible, for example, to avoid data collisions between ROM, with a long output
floating time, and high-speed memory, I/O interfaces, and so on.
(1) Consecutive Reads between Different Areas
If consecutive reads between different areas occur while the ICIS1 bit in BCRH is set to 1, an idle
cycle is inserted at the start of the second read cycle.
Figure 6-17 shows an example of the operation in this case. In this example, bus cycle A is a read
cycle from ROM with a long output floating time, and bus cycle B is a read cycle from SRAM,
each being located in a different area. In (a), an idle cycle is not inserted, and a collision occurs in
cycle B between the read data from ROM and that from SRAM. In (b), an idle cycle is inserted,
and a data collision is prevented.
T1
Address bus
RD
Bus cycle A
;
Data bus
T2
T3
T1
T2
Bus cycle B
Bus cycle A
Bus cycle B
Long output
floating time
Data
collision
(a) Idle cycle not inserted
(ICIS1 = 0)
(b) Idle cycle inserted
(Initial value ICIS1 = 1)
T1
Address bus
RD
Data bus
T2
T3
TI
T1
T2
CS (area A)
CS (area B)
CS (area A)
CS (area B)
Figure 6-17 Example of Idle Cycle Operation (1)