![](http://datasheet.mmic.net.cn/Exar-Corporation/XRT79L71IB-F_datasheet_100145/XRT79L71IB-F_491.png)
PRELIMINARY
XRT79L71
476
REV. P2.0.0
1-CHANNEL DS3/E3 CLEAR-CHANNEL FRAMERLIU COMBO - CC/HDLC ARCHITECTURE
NOTE: This setting will configure the Transmit LAPD Controller to handle LAPD/PMDL messages that contain 76-byte sized
Information Payloads.
If an ITU Path Identification type of PMDL Message is to be transmitted, write the value "1" into the Transmit
LAPD Message Length bit-field, as depicted below.
NOTE: This setting will configure the Transmit LAPD Controller to handle 82-byte sized PMDL Messages.
STEP 6 - Load the Transmit LAPD Message Buffer
The next step is to load in the contents of the outbound PMDL/LAPD Message into the Transmit LAPD
Message Buffer. Whenever the user wishes to load in the contents of the outbound PMDL/LAPD Message into
the Transmit LAPD Message buffer, then the user MUST employ the Indirect Addressing scheme that will be
presented below.
In order to begin the process of loading in the contents of the outbound PMDL Message, the user must be
aware of the following important Address Locations, within the XRT79L71 Address space.
1.
The LAPD Message Buffer - Indirect Address Register - Address = 0x11C0
2.
The LAPD Message Buffer - Indirect Data Register - Address = 0x11C1
By performing READ or WRITE operations to these two registers, the user can actually obtain READ/WRITE
access to both the Transmit LAPD Message Buffer and the Receive LAPD Message Buffer. This section will
describe the approach that one should use to access the Transmit LAPD Message Buffer. The approach that
one should use to access the Receive LAPD Message buffer will be presented in SEE”RECEIVING The exact approach that one should use, when loading the contents of their PMDL Message into the Transmit
LAPD Message buffer is presented below.
STEP 6a - Write the value "0x7E" into the very first byte-position, within the Transmit LAPD Message
Buffer
This is accomplished by executing the following two sub-steps.
Sub-STEP 6a.1 - At Address Location 0x11C0 (the LAPD Message Buffer - Indirect Address Register)
write in the value "0x00".
Transmit E3 LAPD Configuration Register (Address = 0x1133)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LAPD
Any
Unused
Auto
Retransmit
Unused
Transmit
LAPD
Message
Length
Transmit
LAPD
Enable
R/W
RO
R/O
R/W
R/O
R/W
0
X
0
1
Transmit E3 LAPD Configuration Register (Address = 0x1133)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
LAPD
Any
Unused
Auto
Retransmit
Unused
Transmit
LAPD
Message
Length
Transmit
LAPD
Enable
R/W
RO
R/O
R/W
R/O
R/W
0
X
0
1