CardBus Socket Registers (Function 0)
133
September 2005
SCPS110
6.6
Socket Power Management Register
This register provides power management control over the socket through a mechanism for slowing or
stopping the clock on the card interface when the card is idle. See Table 67 for a complete description of the
register contents.
CardBus register offset:
CardBus Socket Address + 20h
Register type:
Read-only, Read/Write
Default value:
0000 0000h
BIT NUMBER
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESET STATE
0
BIT NUMBER
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESET STATE
0
Table 67. Socket Power Management Register Description
BIT
SIGNAL
TYPE
FUNCTION
3126
RSVD
R
Reserved. These bits return 00 0000b when read.
25
SKTACCES
R
Socket access status. This bit provides information on whether a socket access has occurred. This bit is
cleared by a read access.
0 = No PC Card access has occurred (default).
1 = PC Card has been accessed.
24
SKTMODE
R
Socket mode status. This bit provides clock mode information.
0 = Normal clock operation
1 = Clock frequency has changed.
2317
RSVD
R
These bits return 000 0000b when read.
16
CLKCTRLEN
RW
CardBus clock control enable. This bit, when set, enables clock control according to bit 0 (CLKCTRL).
0 = Clock control disabled (default)
1 = Clock control enabled
151
RSVD
R
These bits return 0s when read.
0
CLKCTRL
RW
CardBus clock control. This bit determines whether the CardBus CLKRUN protocol attempts to stop or
slow the CardBus clock during idle states. The CLKCTRLEN bit enables this bit.
0 = Allows the CardBus CLKRUN protocol to attempt to stop the CardBus clock (default)
1 = Allows the CardBus CLKRUN protocol to attempt to slow the CardBus clock by a factor of 16.
This bit is cleared only by the assertion of GRST.