Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current rating range
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
DC 28 V (AC 250: suffix 051034)
0.05...16 A (up to 25 A to special order)
5,000 operations at 2 x I
N
-20...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 1500 V
> 100 M
(DC 500 V)
0.05...2.5 A
3...5 A
6...16 A (25 A) 400 A
operating area IP 40
terminal area IP 00
8 g (57 to 500 Hz/
±
0.61 mm, 10-57 Hz),
to IEC 68-2-6, Test Fc,
25 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 35 g
8 x I
N
20 x I
N
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal Automotive Circuit Breaker 2-5200-...
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-
free, snap action mechanism (R-type TO CBE to EN 60934; M-type
when fitted with optional manual release feature). Designed for plug-in
mounting with E-T-A sockets 10 and 16. The optional -KF housing is
particularly suited to high humidity and other damp conditions.
Description
Technical data
2-5200-...
Typical applications
Extra low voltage wiring systems and components.
Accessories
10R-K10
Modular snap-together surface mounted sockets, each
accommodating two plug-in circuit breakers. With screw terminals.
As above but with push-on terminals.
As above but with a combination of screw and push-on terminals.
Two-way brass connecting/bus bar links for type 10 sockets.
Four-way brass connecting/bus bar links for type 10 sockets.
Single socket for symmetric EN rail mounting.
Adapter for mounting socket type 16 to asymmetric rail
(G-profile).
Blanking plug with insulated pins, for sockets 10, 20, 40, 60.
10R-P10
10R-A10
Y 301 166 02
Y 301 166 01
16
X 200 409 01
Y 301 477 01
Ordering information
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
1.8
2
Internal
resistance (
)
280
100
110
29
14
7
4.9
3.4
2.5
1.8
1.2
0.84
0.6
0.4
0.25
Current
rating (A)
2.5
3
3.5
4
4.5
5
6
7
8
10
12
13
15
16
Internal
resistance (
)
0.2
0.1
0.065
0.065
0.05
0.05
0.02
0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Approvals
Authority
LRoS
Semko
Voltage ratings
AC 250 V; DC 28 V
AC 250 V; DC 28 V
Current ratings
0.05...16 A
0.05...16 A
Type No.
2-5200
plug-in
Manual release
(optional)
H
manual release facility
Special housing
(optional)
KF
for tropical and high humidity conditions
Special version
051034
Voltage rating AC 250 V
Current ratings
0.05 ... 16 A
2-5200 - H - - 051034 - 5 A
ordering example
The exact part number required can be built up from the table of choices shown