Issue C
4
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
235
Voltage rating
Current rating range
Auxiliary circuit
Typical life
AC 115 V (400 Hz); DC 28 V
1...25 A
0.5 A, DC 28 V
20,000 operations mechanical or
10,000 operations at I
N
-55...+125
°
C
Rated impulse
withstand voltage degree
1.5 kV
Ambient temperature
Insulation co-ordination
(IEC 664 and 664A)
Pollution
3
Dielectric strength
(IEC 664 and 664A)
operating area
main to aux. circuit
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 1500 V
AC 1500 V
>100 M
(DC 500 V)
AC 115 V (400 Hz):
≤
4 A
7.5...25 A
DC 28 V: 1...25 A 6000 A
operating area IP 40
terminal area IP 00
1000 A
2000 A
2500 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
(sinusoidal)
15 g (70-2000 Hz)
±
0.76 mm (5-70 Hz)
to VG 95210, sheet 19/
IEC 68-2-6, test Fc/ISO 7137
16.4 g rms, 0.2 g
2
/Hz
±
1.5 dB
to VG 95210, sheet 29/ISO 7137
17 g, to ISO 2669
75 g (11 ms)
to VG 95210, sheet 28/
IEC 68-2-27, test Ea/ISO 7137
96 hours at 5 % salt mist, severity A
48 hours at 20 % salt mist, severity B
to VG 95210, sheet 2/
IEC 68-2-11, test Ka/ISO 7137
240 hours at 95 % RH
to VG 95210, sheet 7/
IEC 68-2-3, test C/ISO 7137
to VG 95210, sheet 10/
MIL-STD-202, meth. 109
≤
25,000 m above sea level
max. 29 g with auxiliary contact
max. 25 g without auxiliary contact
with aluminium threadneck:
max. 26 g with auxiliary contact
Vibration (random)
Acceleration
Shock
Corrosion
Humidity
Explosion
Altitude
Mass
High Performance Thermal Circuit Breaker 483-...
Technical data
Description
483-...
without auxiliary contact with auxiliary contact
Single pole, miniaturised, aircraft style thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band on
the push button shows clearly the tripped/off position. Threadneck
panel mounted, available in metric and US (MS 3320) configurations.
Advanced two-chamber design contributes to fail-safe operation.
Temperature compensated from -55
°
to +125
°
C, with optional auxiliary
contacts, and fully approved for use on a wide range of aircraft and
equipment. Full military specification ensures suitability for the most
demanding applications. For three pole version see type 583.
Aircraft systems and equipment (fixed wing and helicopters); other
extra low voltage wiring applications; defence equipment;
communications systems.
Typical applications
X 200 801 08
Water splash cover/hex nut assembly. The concertina
design is extended when the button trips to the OFF
position. Plated finish.
As above but blackened finish.
As above, but hex nut 7/16-32, black finish
Splash seal/hex nut assembly, allowing full visibility of
the push button actuator. Plated finish.
As above but blackened finish.
Screw-tightened clamp-on actuator extension to aid
manual operation.
X 200 801 03
X 200 801 09
X 200 802 01
X 200 802 02
X 200 803 01
Accessories
Standard current ratings and typical volt drop values
7.5
10
15
20
25
230
190
190
200
170
1
2
2.5
3
4
5
750
520
400
360
350
260
Current
rating (A)
Volt drop
(mV)
Current
rating (A)
Volt drop
(mV)
Approvals
LN 29886
VG 95345, part 06
prEN 2995
MS 3320,
QPL USA, Canada, UK, Sweden