139
Issue C
2
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Circuit Breaker
Main circuit:
voltage rating
current rating range
standard current ratings
AC 250 V (50/60 Hz); DC 48 V
0.05...10 A
0.1 0.2 0.3 0.4 0.5 0.6 0.8 A
1 1.5 2 2.5 3 4 5 A
6 8 10 A
Auxiliary circuit:
voltage rating
current rating
Other data
Front plate
Dimensions:
width
height
Material
LED
Max. voltage rating
AC 250 V/DC 28 V
1 A
see type 2215
4 TE (1 TE = 5.08 mm)
3 HE (1 HE = 44.45 mm)
aluminium, anodized
DC 24 V
E2215-...
Thermal-magnetic circuit breaker mounted on Euro Card for 19" rack
mounting, with one Euro Card accommodating up to three circuit
breakers. Convenient toggle actuation enables series 2210 additionally
to be used as an ON/OFF switch. A red LED is located in the front frame
of the Euro Card, indicating the switching status of the circuit breaker
(via the auxiliary circuit).
Process control, measuring and control systems,
telecommunications.
Description
Typical applications
Technical data
Ordering information for circuit breakers only
Thermal-Magnetic Circuit Breaker E2215 for 19" Rack Mounting
Type No.
E2215
Mounting
1 3 x 1 pole, mounted symmetrically (standard)
2 2 x 1 pole, mounted centrally above and below
3 2 x 1 pole, mounted above and below
4 2 x 1 pone, mounted below and centrally
5 1 x 1 pole, mounted above
6 1 x 1 pole, mounted centrally
7 1 x 1 pole, mounted below
Handle
1
aluminium handle (standard)
LED
1
red LED, DC 24 V (standard)
Circuit breaker
Actuator design
L2
moulded toggle
Number of poles
1
single pole protected
Accessories
0
without
Terminal design
P1
blade terminals A6.3-9,8 (standard)
Characteristic curve
01
F1 fast acting: therm. 1.01x1.4 I
N
;
magn. 2-4xI
N
DC (DC only)
02
M1 standard delay: therm. 1.01-1.4xI
N
;
magn. 5-10xI
N
DC; magn. 3.5-8xI
N
DC
03
T1 delayed: therm. 1.01-1.4xI
N
;
magn. 6-13xI
N
AC
Auxiliary contacts
S1 with auxiliary contacts (change over)
Auxiliary contact - terminal design
1
same as main terminals
Current ratings
0.05...10 A
E2215 - 3 1
1 - L2
1
0 - 02 - S1 1 - 0.1 A ordering example
Select the circuit breakers to above ordering information. For further
information please refer to pages 135 - 137.
It is possible to fit circuit breakers of mixed current ratings on the Euro
Card.
Please add "Circuit breakers to be mounted on Euro Card" to the circuit
breaker designation when ordering so that the applicable suffix number
for the special version (E2215-L2..) can be determined .
19" racks may also be fitted with one or two circuit breakers by the
customer, using industry standard components such as base plates,
front plates with handle, sockets. Connection by means of blade
terminals 6.3x0.8 mm.