279
Issue C
5
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
Bimetal operated current sensitive relay for disconnection of auxiliary
windings and start capacitors of single phase AC motors. The operating
time of the auxiliary winding is a function of the starting current and its
duration. High contact pressure reduces sensitivity to shock and
vibration - no contact sticking.
Other features: independent of mounting position and location. Under
stalled motor conditions the auxiliary winding and/or the starting
capacitor will remain disconnected avoiding damage to the motor.
See page 281 for additional information.
Motor Start Switch 2-7000-...
Description
Typical applications
Single phase AC motors
Ordering information
Technical data
2-7000-...
Standard current ratings and typical internal resistance values
Current
rating (A)
0.2
0.5
0.8
1
1.3
1.5
1.8
2
Internal
resistance (
)
91
16
6
3.65
2.17
1.62
1.10
0.97
Current
rating (A)
2.5
3
4
5
6
7
8
10
Internal
resistance (
)
0.53
0.435
0.342
0.27
< 0.02
< 0.02
< 0.02
< 0.02
Approvals
Authority
VDE
Voltage rating
AC 250 V
Current rating
0.1...10 A
Voltage rating
Current rating of
switching circuit
Current rating of
excitation circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664A)
AC 250 V, 50/60 Hz
10 (5) A
0.2...10 A
100,000 operations at 1xI
N
0...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
Pollution
3
Dielectric strength
(IEC 664 and 664A)
Insulation resistance
Interrupting capacity
Degree of protection
(IEC 529/DIN 40050)
Vibration
Test voltage AC 2,000 V
>100 M
(DC 500 V)
4 x I
N
(co-co-co)
housing IP 30
terminal area IP 00
5 g (57-500 Hz)
±
0.38 mm (10-57 Hz)
to IEC 68-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
test to IEC 68-2-27, Test Ea
48 hours at 5 % salt mist
to IEC 68-2-11, test Ka
240 hours at 95 % RH
test to IEC 68-2-3, test Ca
approx. 18 g
Shock
Corrosion
Humidity
Mass
Type No.
2-7000
motor start switch
Terminal design
P10
blade terminals 6.3-0.8
Housing
(optional)
KF
for tropical and high humidity conditions
Current ratings
0.2...10 A
2-7000 - P10 - KF - 6 A ordering example