Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Standard current ratings and typical internal resistance values
Current
ratings (A)
0.05
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
Internal
resistance (
)
440
108
29.9
14.2
7.9
5.0
3.5
1.8
1.19
Current
rating (A)
1.5
2
2.5
3
4
5
6
8
≤
0.02
10
≤
0.02
Internal
resistance (
)
0.54
0.33
0.20
0.14
0.084
0.057
0.043
Voltage rating
AC 250 V, 50/60 Hz; DC 48 V
(higher DC voltages to special order)
0.05...10 A
1 A, AC 250 V/DC 28 V
10,000 operations at 1xI
N
-30...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Pollution
2
Dielectric strength
IEC 664 and 664A)
operating area
main/aux. circuit
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077)
Test voltage
AC 3000 V
AC 1500 V
> 100 M
(DC 500 V)
300 A
I
N
0.05 A
0.1...6 A
8...10 A
0.05...10 A
operating area IP 30
terminal area IP 00
Curve F1:
6 g (57-500 Hz),
±
0.46 mm (10-57 Hz)
Curves M1, T1:
8 g (57-500 Hz),
±
0.61 mm (10-57 Hz)
to IEC 68-2-6, Test Fc
10 frequency cycles/axis
Curves F1, M1, T1:
30 g (11 ms), directions 1, 2, 3, 4, 5,
Curve F1: 10 g (11 ms), direction 6
Curves M1, T1: 15 g (11 ms), direction 6
to IEC 68-2-27, Test Ea
96 hours at 5 % salt mist
to IEC 68-2-11, Test Ka
240 hours at 95 % RH
to IEC 68-2-3, Test Ca
approx. 25 g
U
N
AC 250 V
AC 250 V
AC 250 V
DC 50 V
200 A
1000 A
2000 A
200 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal-Magnetic Circuit Breaker 2215-L.../G...
Miniaturised single pole thermal-magnetic circuit breakers with trip-
free, snap action mechanism and toggle actuation (S-type TM CBE to
EN 60934). Two designs provide the option of either printed circuit
board or threadneck panel mounting. A separate shunt tap terminal and
auxiliary contacts are available. Fast acting, medium or long delay
characteristics can be specified for both models.
Complies with CBE standard EN 60934 (IEC 935).
Control equipment, communications systems, instrumentation.
Description
Typical applications
Ordering information
Technical data
2215-L1..
2215-G1..
Type No.
2215
single pole thermal-magnetic circuit breaker
Mounting
G1
threadneck panel mounting
L1
PCB mounting
Number of poles
1
1 pole protected
Mounting hardware
0
without accessories
1
2 hex nuts 1/4"-40 UNS-2A, serrated washer,
location pin (-G1 only)
Terminal design (main contacts)
P1
blade terminals 6.3-0.8 without shunt terminal
B1
blade terminals 6.3-0.8, with shunt terminal
L1
solder pins, without shunt terminal
M1 solder pins, with shunt terminal
Characteristic curve
F1
fast acting: 1.01-1.4xI
N
;
magn. 2-4xI
N
DC (DC only)
M1
standard delay: therm. 1.01-1.4xI
N
;
magn. 5-10xI
N
DC;
magn. 3.5-8xI
N
AC
T1
delayed: therm. 1.01-1.4xI
N
;
magn.10-16xI
N
AC
Auxiliary contacts
S0 without auxiliary contact
S1 with auxiliary contact (change over)
Auxiliary contact - terminal design
1
2
blade terminals 6.3x0.8 -G1
solder pins
Current ratings
0.05...10 A
-L1
2215 - G1
1 1 - P1
F1 - S1 1 - 0.5 A
ordering example