267
Issue C
5
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current rating of
switching circuit
Operating voltages
Switching/
reset times in sec
AC 250 V (50/60 Hz); DC 24 V
5 (2) A
AC 4...240 V
approx. 20
approx. 25
approx. 30
The sum of switching time and reset time
should be between 60 and 120 s
100,000 operations at 1xI
N
-30...+60
°
C
Rated impulse
Pollution
withstand voltage degree
2.5 kV
3
approx. 40
approx. 50
approx. 60
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Dielectric strength
(IEC 664 and 664A)
excitation circuit/
switching circuit
Insulation resistance
Overexcitation
Test voltage
AC 2,000 V
>100 M
(DC 500 V)
1.4 U
N
continuously
up to 3 U
N
short-time
housing IP 30
terminal area IP 00
5 g (57-500 Hz)
±
0.38 mm (10-57 Hz)
to IEC 68-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 68-2-27, test Ea
48 hours at 5 % salt mist
to IEC 68-2-11, test Ka
240 hours at 95 % RH
test to IEC 68-2-3, test Ca
approx. 31 g
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Voltage activated bimetal operated time delay relay with changeover
contact and snap action mechanism, excitation circuit and switching
circuit electrically separate, operation independent of mounting attitude.
High shock resistance. Delay times can be factory-preset as desired.
The continuous excitation voltage may be up to 1.4 times the rated
value. To shorten the switching time the excitation voltage may be
increased to 3 times the rated value but only for that switching time
period.
Time Delay Relay 664-...
Description
Ordering information
Technical data
664-...
Process control, diesel engine pre-heaters
Typical applications
Type No.
664 thermal time delay relay with changeover contact
Terminal design
P10
5 blade terminals 6.3x0.8
P19
printed circuit board pins
Operating voltage*
AC 4...240 V
Switching time*
20...60 sec
Reset time*
20...60 sec
664 - P10 - 230 V - 20 - 40 ordering example
*Please indicate the desired switching time, reset time and operating voltage when
ordering. The sum of switching and reset time should be between 60 and 120 s.
Operating
voltage (V)
4
6
8
10
12
16
20
Internal
resistance (
)
3.4
7.6
16
26.5
40
73
134
Operating
voltage (V)
24
48
60
115
230
240
Internal
resistance (
)
200
725
1,200
4,000
16,700
16,700
Standard operating voltages and typical internal resistance values