212
4
Issue C
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
Dimensions
Internal connection diagram
Typical time/current characteristics
412-...-FN 6...25 A
10000
412-K54-FN2/N2
412-K14/K54-FN2/N2
412-K14-LN2
412-K14/K54-LN2
Splash cover/hex nut assembly
with O ring (IP 66)
X 200 801 08
nickel plated nut,
translucent cover
X 200 801 03
matt black finish nut,
black cover
Splash cover black/hex nut assembly
with O ring (IP 54)
X 200 802 01
nickel plated nut
X 200 802 02
matt black finish nut
Actuator extension
(black)
X 200 803 01
Accessories (approved to VG 95345, part 23)
High Performance Thermal Circuit Breaker 412-...
412-..LN 7,5...35 A
10000
2
line 1
+23
°
C
-55
°
C
+75
°
C
0.001
T
T
1
2
4 6 8
10
… times rated current
20
40
1000
100
10
1
0.1
0.01
6080100
1
2
4 6 8
10
… times rated current
20
40
1000
100
10
1
0.1
0.01
0.001
6080100
+23
°
C
-55
°
C
+75
°
C
M12x1
Time/current characteristics are calibrated at 23
°
C (see page 8). For operation
at other temperatures please apply the factors below to determine the circuit
breaker rating required.
Ambient temperature
°
C
-20 -10 0 +23 +40 +50 +60
Multiplication factor
0.76 0.84 0.92 1 1.08 1.16 1.24