Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current ratings
Typical life
AC 240 V; DC 48 V (DC 50 V UL/CSA)
0.05...16 A
0.05...3 A 3000 operations at 2 x I
N
3.5... 8 A 1000 operations at 2 x I
N
10... 16 A 50 operations at 2 x I
N
Ambient temperature -20...+60
°
C (T 60)
Insulation co-ordination
(IEC 664 and 664 A)
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
pole/pole
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 3000 V
AC 1500 V
> 100 M
(DC 500 V)
0.05...3 A 6 x I
N
3.5... 8 A 8 x I
N
10... 16 A 120 A
I
N
0.05...16 A
0.05...7 A
8...16 A
operating area IP 40
terminal area IP 00
10 g (57-500 Hz)
±
0.76 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 13 g
Interrupting capacity
(UL 1077)
U
N
DC 50 V
AC 250 V
AC 250 V
200 A
1000 A
2000 A
Degree of protection
(IEC 529/DIN 40 050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal Overcurrent Circuit Breaker 1140-... (2 pole)
Ordering information
Technical data
Current
rating (A)
0.05
0.06
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
Internal
resistance (
)
345
240
142
88
24
9.9
5.9
3.7
2.2
1.9
1.4
0.9
0.6
0.5
Current
rating (A)
1.8
2
2.5
3
3.5
4
5
6
7
8
10
12
15
16
Internal
resistance (
)
0.3
0.3
0.2
0.1
0.06
0.04
0.03
0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Standard current ratings and typical internal resistance values
Authority
VDE
UL, CSA
Kema (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
AC 250 V; DC 50 V
AC 240 V; DC 48 V
Current ratings
0.05...16 A
0.05...16 A
0.05...16 A
Approvals
1140-G.5.
Description
Miniaturised double pole thermal circuit breaker with push-to-reset tease-
free, trip-free, snap action mechanism (R-type TO CBE to EN 60934).
Threadneck panel mounting. Suitable for line and neutral switching - the
thermal actuator operating on one pole simultaneously opens both poles
under overload conditions. Approved to CBE standard EN 60934 (IEC 934).
Typical applications
Accessories
Motors, transformers, solenoids, hand-held machines and appliances.
Especially suited to AC duties where the correct orientation of line/
neutral is not known/cannot be guaranteed.
X 201 285 01
Water splash cover/knurled nut assembly.
Type No.
1140
double pole threadneck panel mounting
Mounting
G0 threadneck panel mounting without mounting hardware
G1 threadneck panel mounting with hex nut and knurled nut *
G2 threadneck panel mounting for standard fuseholder cut-out *
G4 threadneck panel mounting with metal knurled nut*
Number of poles
5 double pole, 1 pole protected
Actuator style
1
black push button
Terminal design
P7
blade terminals DIN 46244-C
Characteristic curve
M1
medium delay
Current ratings
0.05...16 A
1140 - G1 5 1 - P7 M1 - 16 A
ordering example
*mounting hardware bulk shipped