271
Issue C
5
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current ratings
for circuit 4-5 (
μ
)
for circuit 6-7
Operating voltages 3-4
Typical life
for circuits 4-5
for circuits 6-7
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
AC 250 V, 50/60 Hz
6 A (6 A) switch on only
6 A (6 A) switch on only
AC 120...AC 240 V
5,000 operations at 1xI
N
5,000 operations at 1xI
N
0...+80
°
C T 80
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation at locking aperture
Pollution
3
Dielectric strength
(IEC 664 and 664A
locking aperture
circuit 3-4-5/6-7
Insulation resistance
Degree of protection
(IEC 529/DIN 40050)
Vibration
Test voltage
AC 4,000 V
AC 2,000 V
>100 M
(DC 500 V)
locking aperture IP 33
terminal area IP 00
5 g (57-500 z),
±
0.38 mm (10-57 Hz)
to IEC 68-2-6, test Fc,
10 frequency cycles/axis
15 g (11 ms)
to IEC 68-2-27, test Ea
48 hours at 5 % salt mist
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
F1: 3...10 N
F3: < 68 N
F1:
≥
400 N
F3:
≥
200 N
approx. 46 g
Shock
Corrosion
Humidity
Operating force
Locking force
Mass
Door Locking Relay 6110-...
Description
Typical applications
Ordering information
Technical data
Bimetal operated voltage activated door lock for washing machines,
ensuring compulsory and permanent contact separation when the door
is forced open. With standard keyed connectors.
Washing machines
6110-F10.-P1X.-...
6110-F30.-P1X.-...
Authority
VDE, Kema, SEV,
Fimko,Demko, Nemko,
IMQ
Voltage ratings
AC 250 V
Current ratings
16 (6) A
Approvals
Type No.
6110
voltage activated door locking relay
Configuration/mounting method
F flange mounting
Lock
1 for door catch
3 for door pin
Number of poles
0 unprotected on all poles
Circuit variants
1...6 see circuit variants shown overleaf
Terminal design
P1 blade terminals 6.3-0.8
Characteristic curve
X0
X2
switch only (version -F..6) (without lock)
standard curve: 230 V
locking time
≤
10 s
release time: 40-100 s (at 23
°
C)
standard curve: 110 V
locking time:
≤
16 s
release time: 40-100 s (at 23
°
C)
Slide positioning
R1
with locating position
Rating
operating voltage in V
X3