Type No.
Description
Max. voltage rating
Current rating of switching
circuit/auxiliary contact
Operating voltages or
currents
Typical life
Overexcitation or
interrupting capacity
Approvals
Available options
Dimensions
Internal wiring diagrams
664-...
Bimetal operated voltage activa-
ted time delay relay, with change
over contact and snap action
mechanism. Excitation circuit and
switching circuit are electrically
separate
AC 250 V (50/60 Hz); DC 24 V
5 (2A)
AC 4...240 V
100,000 operations with 1 x I
N
1.4 U
N
continuously
up to 3 U
N
short-time
see pages 267 - 268
6110-...
Bimetal operated voltage acti-
vated door lock for washing
machines
AC 250 V (50/60 Hz)
4-5/6-7 6A (6A)
switch-on only
AC 120...240 V
5,000 operations with 1 x I
N
for circuit 4-5
5,000 operations with 1 x I
N
for circuit 6-7
VDE, KEMA, SEV, Fimko,
Demko, Nemko, IMQ
see pages 271 - 272
6110-...1-...
683-...
Bimetal operated voltage or cur-
rent activated door locking relay.
Choice of actuator lengths.
Aux. contact optional
AC 250 V (50/60 Hz)
2 (0.3) A
16 (4) A switch on only
0.1...5 A
AC 24...240 V
10,000 operations with 1 x I
N
VDE, Demko, Nemko, Semko,
Fimko, Kema, SEV, VE, IMQ, UTE
see pages 269 - 270
current-activated
Time Delay Relays - Door Locking Systems
60
3
5
3
4
1
2
4
5
3
1
2
2
12.5
6
5
2
3
60
1
2
6(6)A
0(0)A
ON
OFF
6(6)A
0(0)A
ON
OFF
3
4
5
6
7
42
6
60
±