Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current rating range
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
AC 250 V; DC 28 V
0.05...25 A
5,000 operations at 2 x I
N
-20...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 3000 V
> 100 M
(DC 500 V)
0.05...2.5 A 8 x I
N
3... 5 A
6...12 A
(higher interrupting capacity available
to special order)
13...25 A
400 A
20 x I
N
200 A
Interrupting capacity
(UL 1077)
I
N
0.05...4.5 A
5... 7 A
8...16 A
0.05...16 A
operating area IP 40
terminal area IP 00
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 29 g
U
N
AC 250 V
AC 250 V
AC 250 V
DC 28 V
200 A
1000 A
2000 A
200 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal Overcurrent Circuit Breakers 2-5000/2-5700-...
Description
Single pole thermal circuit breaker with press-to-reset, tease-free, trip-
free, snap action mechanism. Type 2-5000 is available with optional
manual release (-H), type 2-5700 can be supplied as a push-push
switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset
configuration: M-type when fitted with manual release -H; S-type with
push-push operation). Fitted with flange or threadneck for panel
mounting. Options include an additional unprotected circuit tap (-A3)
and -KF housing particularly suited to high humidity and other damp
conditions. Approved to CBE standard EN 60934 (IEC 934).
Technical data
2-5000-... 2-5700-...
Typical applications
Motors, transformers, solenoids, battery chargers, power supplies,
appliances, machinery, extra low voltage systems.
Ordering information
Accessories
For types 2-5000 and 2-5700
Y 303 563 01
Ten-way connecting/bus bar for use with circuit
breakers with screw terminals.
For type 2-5000
Y 300 728 01
Y 301 056 02
Y 300 476 01
For type 2-5700 with IG1 threadneck
X 200 799 02
Water splash cover/knurled nut assembly.
X 200 799 01
As above with the cover bonded to the nut for extra
retention.
X 200 798 01/02 As X 200 799 02 and 01 above but featuring a slotted
knurled ring for wrench front of panel tightening.
X 210 739 01
Water splash cover/hex nut. The concertina design
is extended when the button trips to the OFF position.
For type 2-5700 with IG2 threadneck
X 210 663 01
Water splash cover/knurled nut assembly.
X 201 296 01
Water splash cover/hex nut assembly - without
'O'ring.
X 200 801 03
Water splash cover/hex nut assembly - with 'O'ring.
Separate hardware
Y 300 192 01
3/8" hex nut.
Y 300 284 02
3/8" knurled nut.
Y 300 116 02
12 mm hex nut.
Y 300 065 01
12 mm knurled nut.
X 200 801 08
Water splash cover, transparent, with hex nut,
with O ring
Water splash cover for type 2-5000.
Fixing plate for Y 300 728 01.
Rear terminal shroud.
Type No.
2-5000 flange mounting
2-5700 threadneck panel mounting
Threadneck design
IG1
moulded threadneck 3/8"-27UNS-2A (type 2-5700 only)
IG2
moulded threadneck M12x1 (type 2-5700 only)
Terminal design
P10
blade terminals 6.3-0.8 mm
K10
screw terminals M4x6
Shunt terminal
(optional) -P10 only
A3
shunt terminal (up to I
N
2.5 A/6 A max. load)
Manual release
(optional)
H
manual release facility (type 2-5000 only)
DD
push to release/push to reset (type 2-5700 only)
Special housing
(optional)
KF
for tropical and high humidity conditions
Current ratings
0.05 ... 25 A
2-5700 - IG1 - P10 - - DD - - 8 A ordering example
The exact part number required can be built up from the table of choices shown