55
Issue C
1
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
0.63
0.8
1
1.25
1.5
1.8
2
2.5
1.2
1.0
0.7
< 0.8
< 0.8
< 0.8
< 0.8
< 0.5
3.15
4
4.5
5
6.3
8
10
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
Voltage rating
Current rating range 1-2
Auxiliary circuit 1-3
AC 240 V; DC 28 V (DC 48 V UL/CSA)
0.63...10 A
0.2 x I
N
max. 1 A, AC 250 V
style -L2 and -G1 only
300 operations at 2 x I
N
(-L2...)
500 operations at 2 x I
N
(-L1../-G1..)
-20...+100
°
C
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity
(o-o-o)
Test voltage
AC 1500 V
> 100 M
(DC 500 V)
0.63...2.5 A 12 x I
N
3.15...10 A 8 x I
N
AC, max. 70
3.15...10 A 10 x I
N
DC
or to UL 1077 at AC 125/DC 48 V: 200 A
operating area IP 40
Degree of protection
(IEC 529/DIN 40050) terminal area IP 00
Vibration
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
20 g (11 ms)
to IEC 68-2-27, test Ea
48 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
96 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 5 g
Shock
Corrosion
Humidity
Mass
Thermal Overcurrent Circuit Breaker 1410-L/-G...
Description
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934). Single
hole threadneck, PCB or integral mounting with a choice of designs.
Miniaturised construction minimises PCB real estate required. Type
1410-L2 and 1410-G1 versions feature changeover contacts suitable
for providing status output signals. Largely temperature-insensitive.
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines, ap-
pliances, instrumentation.
Ordering information
Technical data
1410-L1... 1410-L2... 1410-G1...
Approvals
Authority
VDE
UL, CSA
Voltage rating
AC 250 V; DC 28 V
AC 125 V; DC 48 V
DC 50 V
Current ratings
0.63... 8 A
0.63... 8 A (-L2/-G1)
0.63...10 A (-L1)
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal
resistance (
)
Current
rating (A)
Internal
resistance (
)
Type No.
1410
single pole circuit breaker
Configuration
L PCB mounting
G threadneck panel mounting
Mounting
1 threadneck 3/8-27 UNS-2A (1410-G)
1 PCB 16.3x4.6 grid (1410-L)
2 PCB 10.15x7.62 grid (1410-L)
Number of poles
1 1 pole, thermally protected
Hardware
0
without
1
with hex nut and knurled nut (1410-G only) bulk shipped
Terminal design
L1 solder pins 1.8x0.8 silver-plated (-L1 only)
L2 solder pins 1x0.8 silver-plated (-L2 and -G1 only)
P2 blade terminals A2.8-0.8 silver-plated (-G1 only)
Characteristic curve
F1
fast acting
Actuator
S
manual re-set
Actuator colour
01 black (for -G1.. and -L1..)
02 white (for -L2..)
Current ratings
0.63 ... 10 A
1410-
L 1 1 0 - L1 F1 - S
01 - 0.8 A ordering example