Issue C
4
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
205
Voltage rating
Current rating range
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664A)
AC 250 V; DC 28 V
8...16 A (20...25 A to special order)
4,000 operations at 2 x I
N
-30...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
(threadneck should be earthed/grounded)
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
Degree of protection
(IEC 529/DIN 40050)
Vibration
Test voltage
AC 2000 V
> 100 M
(DC 500 V)
1000 A
operating area IP 40
terminal area IP 00
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz)
to IEC 68-2-6, Test Fc
10 frequency cycles/axis
40 g (11 ms)
to IEC 68-27, Test Ea
48 hours at 5 % salt mist,
to IEC 68-2-11, Test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 35 g
Shock
Corrosion
Humidity
Mass
Single pole high performance version of type 2-5700 (section 1) thermal
circuit breaker, with push-to-reset tease free, trip-free, snap action
mechanism (R-type TO CBE to EN 60 934). Designed for threadneck
panel mounting and for applications with a high fault current switching
requirement.
Description
Extra low voltage systems, industrial equipment.
High Performance Thermal Circuit Breaker 402-...
Typical applications
Technical data
402-...
X 200 799 02
X 200 799 01
Water splash cover/knurled nut assembly.
As above with the cover bonded to the nut for extra
retention.
As X 200 799 02 and 01 above but featuring a slotted
knurled ring for wrench front of panel tightening.
Water splash cover/hex nut. The concertina design
is extended when the button trips to the OFF position.
X 200 798 01/02
X 210 739 01
Accessories
Ordering information
Type No.
402
threadneck panel mounting*
Terminal design
P10
blade terminals 6.3-0.8
K14
screw terminals M4x6
Current ratings
8 ... 16 A
402 - P10 - 10 A
ordering example
*mounting hardware bulk shipped
8
10
12
< 0.02
< 0.02
< 0.02
14
15
16
< 0.02
< 0.02
< 0.02
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal
resistance (
)
Current
rating (A)
Internal
resistance (
)