145
Issue C
2
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V, DC 28 V
DC 50 V
DC 50 V
AC 250 V
Current ratings
0.1...16 A
0.1...16 A double pole
0.1...10 A single pole
0.1...14 A
CSA, UL
Current
ratings
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
Internal resistance
per pole (
)
therm-.magn. therm.
(A)
165
94
42.5
24
20.2
12
9.7
5.40
7.17
4.30
4.9
3
2.65
1.50
1.49
0.9
1.25
0.7
0.74
0.45
0.49
0.29
Current
ratings
Internal resistance
per pole (
)
therm-.magn.
0.20
0.14
0.114
0.092
0.06
0.043
0.030
0.029
0.021
<0.02
<0.02
therm.
0.0785
0.0595
0.0565
0.0435
0.0325
0.0215
0.0215
0.02
0.02
<0.02
<0.02
Voltage rating
Current ratings
Typical life
AC 250 V, 50/60 Hz; DC 50 V
0.1...16 A
50,000 operations at 1xI
N
double pole
30,000 operations at 1xI
N
single pole
-30...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
current path/
current path
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 3000 V
AC 1500 V
>100 M
(DC 500 V)
0.1...2 A 100 x I
N
2.5...16 A
250 A 2 pole
150 A 1 pole
Interrupting capacity
(UL 1077)
I
N
0.1...4 A
5... 10 A
12...14 A
operating area IP 40
(with water splash protection IP 54)
terminal area IP 00
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz)
to IEC 68-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 53 g (2 pole)
approx. 50 g (1 pole)
U
N
AC 250 V
AC 250 V
AC 125 V
200 A
2000 A
1000 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
3120-...-M...
Description
Single or two pole rocker switch/thermal-magnetic circuit breaker (S-
type TM CBE to EN 60934). The addition of a magnetic tripping module
to the type 3120 range described in catalogue section 1 extends the
choices available to include single pole with thermal-magnetic
protection; double pole switching with thermal-magnetic protection on
one pole, thermal protection on the other; double pole switching with
thermal-magnetic protection on one pole only. All are offered with
rocker switch or push button control - two buttons for ON/OFF or one
button press-to-reset only, in designs to suit one of three different panel
cut-out sizes. Neon illumination (filament bulb for low voltages) is
optional. Approved to CBE standard EN 60934 (IEC 934).
Technical data
Y 303 068 01
Insulated cover, snap-fitted to the exposed areas of the
two incoming terminals (when terminal screws are not
specified) to provide brush contact protection.
Retaining clip for -F3 mounting frame for panel
thicknesses under 2 mm.
As above for panel thicknesses under 4 mm.
Blanking piece in -F3 size mounting frame.
Separate water splash cover for use with -F4 and -F5
size mounting frames.
Y 303 675 01
Y 303 675 02
Y 303 885 31
X 210 832 01
Accessories
Motors, machine tools, office equipment, appliances.
Typical applications
2.5
3
3.5
4
5
6
7
8
10
14
16
Standard current ratings and typical internal resistance values
Approvals