Issue C
4
261
%
Germany (0 91 87) 10-0 – USA (847) 827-7600 – UK (01296) 420336 – www.etacbe.com
MIL-C-83383 pending
Voltage rating
Current rating range
Auxiliary circuit
Bias current
Switching current/
switching period
Trigger current for ICU
(“TRIP FREE“-mode)/
duration
Typical life
DC 28 V (DC 18...36 V)
5... 100 A
3 A, DC 28 V, AC 115 V (400 Hz)
2.5 mA max
2.8 A/ 25 ms
approx. 3.2 A /5 s max
50,000 operations at I
N
(inductive or resistive)
-54...+71
°
C
Ambient temperature
Dielectric strength
(IEC 664 and 664A)
between main terminals AC 1500 V
main terminal to
mounting area
Insulation resistance
Interrupting capacity
Vibration
(sinusoidal)
Test voltage
AC 1500 V
> 100 M
(DC 500 V)
DC 28 V: 6000 A
10 g (55-2000 Hz),
±
0.76 mm (10-55 Hz)
to MIL-STD 202, method 204,
condition C
10-2000 Hz, spectral power density
0.15 g
2
/Hz, rms value 13.5 g;
5 h/axis loaded with 0.9 I
N
25 g (11 ms)
to MIL-STD 202, method 213, condition J
ISO 7137 (RTCA/DO-160 C, part 7)
48 hours at 5 % salt mist
to MIL-STD 202, method101, condition B
ISO 7137 (RTCA/DO-160 C, part 14,
category S)
240 hours at 95 % RH
to MIL-STD 202, method 106/ISO 7137
(RTCA/DO-160 C, part 6, category B)
< 15,000 m above sea level
approx. 300 g
Vibration
(random)
Shock
Corrosion
Humidity
Altitude
Mass
Remote Control Circuit Breaker 4910 (RCCB)
Description
Technical data
Single pole remote control circuit breaker (RCCB), temperature
compensated, either with or without auxiliary contacts, and featuring a
bimetal actuator which trips the circuit breaker mechanism within a
specified time under overcurrent conditions. The switching contact
latching system is operated by a bi-stable linear motor controlled by
electronic circuitry incorporated within the device. Applying the system
voltage across the input will switch the RCCB ON, disconnection of the
input will cause it to switch OFF. Remote control is achieved through
the use of a conventional single pole manually operated aircraft style
thermal circuit breaker to connect the supply to the control input of the
RCCB. Complies with the requirements of MIL-C-83383.
4910 (RCCB)
Typical applications
Aircraft electrical systems and equipment, and other high performance
applications.
Ordering information
Standard current ratings and typical voltage drop values
Current
ratings (A)
5
7.5
10
15
20
25
35
Voltage drop at
rated current(mV)
450
360
347
225
200
200
200
Current
ratings (A)
40
50
60
75
80
100
Voltage drop at
rated current(mV)
200
200
200
200
200
200
Approvals
Type No.
4910
single pole remote control circuit breaker (RCCB)
Variation
01
standard, with auxiliary contacts
02
with modified terminal barrier and auxiliary contacts
03
standard, without auxiliary contacts
04
with modified terminal barrier but without auxiliary contacts
Current ratings
5... 100 A
4910 - 01 -
5 A
ordering example