Issue C
4
%
Germany (0 91 87) 10-0 - USA (847) 827 - 7600 - UK (01296) 420336 - www.etacbe.com
243
Voltage rating
Current rating range
Auxiliary circuit
Typical life
3 AC 200 V (400 Hz); DC 28 V
1...25 A
0.5 A, DC 28 V
20,000 operations mechanical
10,000 operations at I
N
-55...+125
°
C (
≤
15 A)
-55...+ 90
°
C (> 15 A)
Rated impulse
withstand voltage degree
1.5 kV
Ambient temperature
Insulation co-ordination
(IEC 664 and 664A)
Pollution
3
Dielectric strength
(IEC 664 and 664A)
operating area
pole/pole
main to aux. circuit
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 1500 V
AC 1500 V
AC 1500 V
>100 M
(DC 500 V)
3 AC 200 V (400 Hz):
≤
4 A
5 A
7.5...25 A
DC 28 V: 1...25 A
operating area IP 40
terminal area IP 00
10 g (57-2000 Hz)
±
0.76 mm (5-57 Hz)
to VG 95210, sheet 19/
IEC 68-2-6, test Fc/ISO 7137
16.4 g rms, 0.2 g
2
Hz
±
1.5 dB
to VG 95210, sheet 29/
IEC 68-2-6, test Fc/ISO 7137
17 g, to ISO 2669
50 g (11 ms)
to VG 95210, sheet 28/
IEC 68-2-27, test Ea/ISO 7137
96 hours at 5 % salt mist
48 hours at 20 % salt mist
to VG 95210, sheet 2/
IEC 68-2-11, test Ka/ISO 7137
240 hours at 95 % RH
to VG 95210, sheet 7/
IEC 68-2-3, test C/ISO 7137
to VG 95210, sheet 10/
MIL-STD-202, meth. 109
≤
25,000 m above sea level
max. 67 g with auxiliary contact
max. 63 g without auxiliary contact
1,000 A
2,000 A
2,500 A
6,000 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
(sinusoidal)
Vibration (random)
Acceleration
Shock
Corrosion
Humidity
Explosion
Altitude
Mass
High Performance Thermal Circuit Breaker 583-...
Description
583-...
with auxiliary contact without auxiliary contact
Technical data
Three pole, miniaturised, aircraft style thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band on
the push button shows clearly the tripped/off position. Threadneck
panel mounted, available in metric and US (MS 14154) configurations.
Advanced two-chamber design minimises contact contamination to
provide fail-safe operation. Temperature compensated with optional
auxiliary contacts, and fully approved for use on a wide range of aircraft
and equipment. For single pole version see type 483.
Aircraft systems and equipment (fixed wing and helicopters); other
extra low voltage wiring applications; defence equipment;
communications systems.
Typical applications
X 200 801 08
Water splash cover/hex nut assembly. The concertina
design is extended when the button trips to the OFF
position. Plated finish.
As above but blackened finish.
As above, but hex nut 7/16-32, black finish
Splash seal/hex nut assembly, allowing full visibility of
the push button actuator. Plated finish.
As above but blackened finish.
Screw-tightened clamp-on actuator extension to aid
manual operation.
X 200 801 03
X 200 801 09
X 200 802 01
X 200 802 02
X 200 803 01
Accessories
Standard current ratings and typical volt drop values
1
2
2.5
3
4
5
750
520
400
360
350
260
7.5
10
15
20
25
230
190
190
200
170
Current
rating (A)
Volt drop
(mV)
Current
rating (A)
Volt drop
(mV)
Approvals
Approvals:
LN 29887
VG 95345, part 11
prEN 2996
MS 14154
QPL USA, Canada, UK, Sweden