6
311
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Issue C
Operating voltage U
B
DC 36 V (28...60 V)
(function maintained up to DC 18 V)
0.25 A/0.4 A/1 A/2 A/3 A
typically 30 mA
Current rating I
Current consumption
(U
= DC 36 V, U
= “0”)
Residual ripple for all voltages max. 5 % (3 phase bridge)
Reverse polarity protection U
B
double pole relay
(terminal 1 - terminal 2)
Physical isolation
2-pole
- by manual circuit breaker release
- approx. 5 s
after short-circuit disconnection
Load circuit
Load output
NPN transistor, minus switching,
pulse-controlled (approx. 180 Hz)
DC 24 V/0.25 A ( 3... 6 W)
DC 24 V/0.4 A ( 6...10 W)
DC 24 V/1 A (15...30 W)
DC 24 V/2 A (30...50 W)
DC 24 V/3 A (50...75 W)
U
B
/R
total
for approx. 400 ms
Load rating
Switch-on current I
(with short-circuit limitation)
Minimum current I
min
(^
)
Short-circuit limitation
Short-circuit current I
K (rms)
(depending on U
and I
N
)
Wire break indication
Current measuring terminals 2 x 2 mm dia. (shunt 0.1
±
1 %)
Leakage current (U
= “0”)
typically 1 mA
Free-wheeling circuitry
integral electronic control with quick
disconnection
Control circuit
Control
opto coupler in control input
Control voltage U
S
“0” = 0 ... 5 V
“1” = 8.5...35 V
Control current I
S
typically 5 mA
Switching frequency f
max
1 Hz
Control signal (U
S
= “1”)
YELLOW LED lights (I
S
flowing)
Protection
reverse polarity protection (diode)
Status outputs
Fault indication
auxiliary contact (N/O)
- max. DC 30 V/3 A
- physically isolated
- closed when the circuit breaker has
tripped
General data
Ambient temperature
0...+60
°
C (without condensation)
Terminals
screw terminals 2x2.5 mm
2
to DIN 46288
Housing
clamping plate: polycarbonate GV, blue;
cover: polycarbonate, black
Mounting
on top-hat rail to DIN 50022-35
Self-extinguishing properties to UL 94: V = 0; VDE 0304: grade 1
Degree of protection
IP 20 housing, terminals
(IEC 529/DIN 40050)
Mounting dimensions
45 x 74 x 128 mm
Mass
approx. 240 g
adjustable between 25 and 75 % I
N
(e.g. 0.5...1.5 A with the 2 A version)
approx. 2 x I
typically 10 mA
in the ON and OFF condition (RED LED)
Technical data
(T
A
= 25
°
C, U
B
= DC 36 V)
Description
Typical applications
Circuits with inductive load such as
- solenoids
- magnetic brakes etc.
where fast switching of inductive loads is required.
Features
E-1071-803
G
Designed for inductive loads (DC 24 V)
G
Individual adjustment to various load currents (I
N
= 0.25 A; 0.4 A;
1 A; 2 A; 3 A)
G
Significant reduction of power loss in the load by pulse-controlled
characteristics
G
Short-circuit proof; short-circuit limitation and physical
disconnection from supply after approx. 5 s
G
Inrush current monitoring
G
Overload protection (current control)
G
Fast disconnection (do not connect a free wheeling diode to the
load as the the free wheeling current is controlled electronically!)
G
Physical isolation:
- opto coupler in the control circuit
- relay contacts in the load circuit
- fault indication by means of auxiliary contact (N/O)
G
Reverse polarity protection in the control and load circuits
G
Control current indication by YELLOW LED
G
Wire break indication by RED LED (load circuit)
G
Minimum current indication by GREEN LED
Ordering information
Solid State Remote Power Controller E-1071-803
The E-T-A Solid State Remote Power Controllers E-1071-803 are
electronic control modules suitable for inductive loads (DC 24 V) such
as solenoids, magnetic brakes etc.
They are used
G
for safe and quick switching of loads
G
for monitoring the electrical condition of the loads
G
for compensating for different cable lengths
The load connected to the relay should be operated with a voltage higher
than its rated voltage (DC 24 V) because the load current is controlled
electronically (pulse-controlled characteristics). This is to ensure that in
industrial plants with different cable lengths (supply cables, load cables)
an increased inrush current can be applied to each load. During hold
duty the load current is reduced to a smaller value (between 25 % and
75 % of the current rating), thus reducing the operating temperature
and extending the life of the loads.
Type No.
E-1071
SSRPC
Operating mode
803
pulse controlled
Voltage rating of load
DC 24 V
Current rating
0.25 A
0.4 A
1 A
2 A
3 A
E-1071 - 803 - DC 24 V - 1 A ordering example