6
299
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Issue C
Voltage rating U
Operating voltage U
B
Current rating I
Current consumption
(U
= DC 48 V, U
= “0”)
Residual ripple for all voltages max. 5 % (3 phase bridge)
Reverse polarity protection U
B
double pole relay
(terminal 1 - terminal 2)
Physical isolation
DC 48 V
DC 36...60 V
3 A/3 A (2 A + 2 A)
typically 21 mA
2-pole
- by manual circuit breaker release
- approx. 5 s after overload
disconnection
- upon thermal response (approx. 130
°
C)
Load circuits (I/II)
Load output
Load rating
NPN transistor, minus switching
DC 48 V/0.2...3 A per channel
parallel duty max. 4 A (e.g. 2 A + 2 A)
max. 1.8 V
approx. 1.1 x I
typically 20 ms (see storage time curve)
approx. 2.5 x I
N
Voltage drop at I
Overload disconnection
Storage time ts (at 2xI
N
)
Short-circuit limitation
Short-circuit response delay approx. 4
μ
s
Load current monitoring
Current measuring terminals 3 x 4 mm dia. (0.1
shunt)
Leakage current (U
S
= “O”)
Free-wheeling diode
Control circuits (I/II)
Control
Control voltage U
S
GREEN LED lights at I
> 0.1 A)
max. 3 mA
integral
opto coupler in control input
“0” = 0 ... 5 V
“1” = 8.5...35 V
typically 5 mA
100 Hz
RED LED lights (I
flowing)
reverse polarity protection (diode)
Control current
Switching frequency f
Control signal (U
S
= 1“)
Protection
Signal output
Fault indication
auxiliary contact (N/O)
- max. DC 30 V/3 A
- physically isolated
- closed when the circuit breaker has
tripped
General data
Ambient temperature
Terminals
0...+60
°
C (without condensation)
screw terminals 2x2.5 mm
2
to
DIN 46288
clamping plate: polycarbonate GV, blue;
cover: polycarbonate, black
top-hat rail to DIN 50022-35
Housing
Mounting
Self-extinguishing properties to UL 94: V = 0; VDE 0304: grade 1
Degree of protection
IP 20 housing, terminals
(IEC 529/DIN 40050)
Mounting dimensions
45 x 74 x 128 mm
Mass
approx. 320 g
Technical data
(T
A
= 25
°
C, U
B
= DC 48 V)
Description
Typical applications
-
Valve timing gears for forward/backward or upward/downward
movements (overlapping operation is possible)
Parallel circuits which must be completely disconnected after
failure of one of the circuits.
-
Features
E-1071-343
The E-T-A Solid State Remote Power Controller E-1071-343 is a double
relay with protective function both for resistive and inductive DC 48 V
loads. It is particularly suitable to control upward/downward and forward/
backward movements. Failure of one channel will also cause the other
channel to disconnect.
G
Small double relay with protective function
G
Overcurrent and short-circuit proof outputs
G
Two pole physical isolation of both channels
- approx. 5 s after electronic fault disconnection
- by manual release
G
Both part units are disconnected upon isolator tripping
G
Current load of each unit: max. 3 A; total current max. 4 A
G
Electrical isolation between control and load circuit by means of
opto coupler
G
Control current indication by RED LED
G
Load current indication by GREEN LED
G
With auxiliary contact (fault indication)
G
Temperature disconnection
Ordering information
Solid State Remote Power Controller E-1071-343
Type No.
E-1071
SSRPC
343
double unit
Voltage rating of load
DC 48 V
Current rating
3A / 3A
E-1071 - 343 - DC 48 V - 3A / 3A ordering example