47
Issue C
1
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current ratings
Typical life
Ambient temperature
Holding current
Reset time at 23
°
C after
5 s of load with U
N
Interrupting capacity
(o-o-o)
Degree of protection
(IEC 529/DIN 40050)
Vibration
DC 12 V
12...30 A
300 operations at 2 x I
N
-30...+60
°
C
< 0.6 A
< 35 sec
200 A, L/R = 2.5 ms
operating area IP 54
terminal area IP 00
5 g (57-500 Hz)
±
0.38 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 6 g
Shock
Corrosion
Humidity
Mass
Thermal Automotive Circuit Breaker 1160-...
Description
Thermal circuit breaker, with controlled self-resetting mechanism,
specially suited to installation in inaccessible locations. Under overload
conditions the circuit breaker contacts will open to protect the load
circuit. A low current excitation circuit ensures that the contacts remain
open thereby avoiding the hazards of automatic reset operation. The
circuit breaker is reset by switching off the supply circuit for a short
period.
Typical applications
Automotive and marine extra low voltage wiring systems and
components.
Technical data
Ordering information
Current rating (A)
12
15
20
30
Voltage drop (mV)
< 150
< 150
< 150
< 150
Standard current ratings and typical voltage drop values
1160-...
Type No.
1160
single pole plug-in type
Design standard
02
standard version 12 V
Current ratings
12, 15, 20, 30 A
1160 - 02 - 12A
ordering example