31
Issue C
1
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
AC 250 V; DC 28 V (type -F)
DC 28 V (type -T)
0.05...25 A
5,000 operations at 2 x I
N
-20...+60
°
C
Rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Pollution
degree
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
Test voltage
AC 3000 V
> 100 M
(DC 500 V)
type -F:
0.05 ...2.5 A
3... 5 A
6...12 A
13...25 A
0.05...2.5 A
3... 5 A
6...25 A
8 x I
N
20 x I
N
200 A
400 A
8 x I
N
20 x I
N
400 A
type -T:
Degree of protection
(IEC 529/DIN 40050)
Vibration
operating area IP 40
terminal area IP 00
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz)
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Db
127-F-..: approx. 24 g
127-T..-: approx. 35 g
Shock
Corrosion
Humidity
Mass
Thermal Overcurrent Circuit Breaker 127-...
Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap
action mechanism (R-type TO CBE to EN 60934: M-type when fitted with optional
manual release feature). Available in versions for plug-in or integral mounting,
track mounting, or with a frame for snap-in panel mounting. The optional -KF
housing is particularly suited to high humidity and other damp conditions.
Approved to CBE standard EN 60934 (IEC 934).
Description
Technical data
127-F-...
127-T11-...
Approvals
Authority
VDE (EN 60934)
CSA, UL
LRoS
Semko (EN 60934)
Type 127-T..- approvals N/A
Voltage ratings
AC 250 V; DC 28 V
AC 250 V
AC 250 V; DC 28 V
AC 250 V; DC 28 V
Current ratings
0.05...25 A
0.1...16 A
0.2...25 A
0.05...25 A
Typical applications
Motors, transformers, solenoids, battery chargers, extra low voltage systems.
Accessories
10F-P10
Modular snap-together surface mounted sockets, each
accommodating two plug-in circuit breakers. With push-on terminals.
As above but with screw terminals.
As above but with a combination of screw and push-on terminals.
Two-way brass connecting/bus bar links for type 10F-K10/-A10
sockets.
Four-way brass connecting/bus bar links.
Fifty-way 1.5mm
2
cable links with pre-fitted connection lugs for
type 10F-K10/-A10 sockets.
As above but with 2.5mm
2
cable links.
100-way 1.5mm
2
cable links with pre-fitted push-on connectors
for type 10F-P10 sockets, brown
As above, but with 2.5mm
2
cable links, black.
As above, but with 2.5mm
2
cable links, red.
As above, but with 2.5mm
2
cable links, blue.
10-F-K10
10F-A10
Y 301 166 02
Y 301 166 01
X 210 589 01
X 210 589 02
X 210 588 01
X 210 588 02
X 210 588 03
X 210 588 04
Ordering information
Current
rating (A)
0.05
0.08
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
0.6
0.7
0.8
0.9
1
1.2
Internal
resistance (
)
280
100
110
56
29
18
14
9.8
7
5.9
4.9
3.4
2.5
1.8
1.5
1.2
0.8
Current
rating (A)
1.5
1.8
2
2.5
3
3.5
4
4.5
5
6
7
8
10
15
16
20
25
Internal
resistance (
)
0.6
0.4
0.3
0.2
0.1
0.06
0.06
0.05
0.05
0.02
0.02
0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Standard current ratings and typical internal resistance values
Type No.
127
Mounting options
leave blank for integral/plug-in option
F
for snap-in mounting
T11
track mounting with captive stud terminals
T12
track mounting with screw terminals
Terminal design
(for use with and without flange -F)
P10
blade terminals A6.3-0.8
K10
screw terminals M4x6
Manual release
(optional)
H
manual release facility
Special housing
(optional)
KF
for tropical and high humidity conditions
Current ratings
0.05...25 A
127 - F - P10 - H - - 10 A
ordering example
The exact part number required can be built up from the table of choices shown above.
Ordering references for optional features should be omitted if not required.