61
Issue C
1
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
AC 250 V; DC 28 V
5...25 A
1000 operations at 2 x I
N
-20...+60
°
C
Rated impulse
withstand voltage degree
2.5 kV
Pollution
2
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077/EN 60934 PC1)
Test voltage
AC 3000 V
> 100 M
(DC 500 V)
200 A
I
N
5...15 A
20...25 A
operating area IP 40
terminal area IP 00
8 g (57-500 Hz)
±
0.61 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
30 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 16 g
U
N
AC 250 V 2000 A
AC 125 V 2000 A
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Thermal Overcurrent Circuit Breaker 1658-...
Description
Very cost effective design to meet international requirements. No
exposed metal parts which are, or could become, current-carrying
except for terminals.
G
Manual reset, trip free mechanism
G
Extremely small and lightweight
G
UL, CSA, VDE approved
Technical data
1658-...
Accessories
Typical applications
Battery chargers, consumer products, power supplies, motors.
Y 306 671 01
Y 303 200 01
Y 300 190 03
Y 302 294 03
Y 300 192 01
Y 302 295 01
Y 301 059 02
Y 302 732 01
Y 303 051 01
X 200 799 01
X 201 285 01
Mounting nut 3/8", 27-thread
Mounting nut 7/16", 28-thread
Knurled nut 3/8", 27-thread
Knurled nut 7/16" - 28-thread
Hex nut 3/8", 27-thread
Hex nut 7/16", 28-thread
Press to Reset Plate for 3/8", 27-thread, aluminium
Press to Reset Plate for 7/16", 28-thread, aluminium
Black Plastic Knurled Nut for 3/8", 27-thread
Reset Button Seal - long
Reset Button Seal - short
Standard current ratings and typical voltage drop values
Current
rating (A)
5
6
7
8
9
Voltage
drop (mV)
≤
150
≤
150
≤
150
≤
150
≤
150
Current
rating (A)
10
12
15
20
25
Voltage
drop (mV))
≤
140
≤
140
≤
240
≤
240
≤
240
Approvals
Authority
VDE
UL, CSA
Voltage rating
AC 250 V; DC 28 V
AC 250 V
AC 125 V
AC 125 V
Current ratings
5...25 A
5...15 A
20..25 A
5...25 A
1658-G...
1658-G...
1658-A...
Ordering information
Type No.
1658
single pole thermal circuit breaker
Threadneck design
G21 manual reset type, 3/8"-27 threadneck
G41 manual reset type, 7/16"-32 threadneck
A21 auto reset type, 3/8"-27 threadneck
A41 auto reset type, 7/16"-32 threadneck
A00 auto reset type, without threadneck
Hardware
00
no hardware
01
one hex nut, bulk
02
one hex nut, one hex nut, bulk
03
one hex nut mounted
04
one hex nut, one hex nut, mounted
05
one hex nut, knurled nut, bulk
06
one knurled nut, bulk
07
one knurled nut, mounted
08
two hex nuts, bulk
Terminals
P10
blade terminals A6.3-0.8
P13
blade terminals A6.3-0.8, 90
°
S80
straight screw terminals*
S83
90
°
bent screw terminals*
Current ratings
5 ... 25 A
1658 - G21 - 02 - P10 - 5 A Ordering example
* Screws and lock washers bulk shipped