106
2
%
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.etacbe.com
Issue C
Thermal-Magnetic Circuit Breaker 2210-S..
Standard current ratings and typical internal resistance values
Current Internal resistance (
)
rating
F1
(A)
fast acting
M1
standard
delay
for AC + DC
92
26.1
11.6
6.6
4.1
3
1.65
1.10
0.47
0.28
0.183
0.124
0.077
0.063
0.045
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
T1
delayed
M3
standard
delay
for AC + DC
42
11.7
5.6
2.9
1.75
1.42
0.75
0.5
0.22
0.136
0.083
0.057
0.041
0.032
0.021
≤
0.02
≤
0.02
≤
0.02
≤
0.02
-
-
T2
thermal
for DC
162
39.3
17.5
9.2
6.8
4.2
2.8
1.6
0.78
0.42
0.26
0.18
0.12
0.092
0.054
0.025
0.022
≤
0.02
≤
0.02
-
-
for AC
81
24.2
10.4
6.0
3.9
2.7
1.53
0.98
0.42
0.24
0.17
0.12
0.073
0.055
0.039
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
for AC + DC
77
23
10.2
5.7
3.7
2.6
1.39
0.9
0.36
0.19
0.141
0.091
0.051
0.040
0.027
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
≤
0.02
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.5
2
2.5
3
4
5
6
8
10
12
16
20
25
Cut-out dimensions 2210-S2...
Installation drawing 2210-S2..
Dimensions 2210-S...
Authority
VDE (EN 60934)
Voltage ratings
AC 250 V, DC 65 V
3 AC 433 V
AC 250 V, DC 65 V
AC 250 V, DC 65 V
3 AC 415 V,
AC 250 V, DC 65 V
Current ratings
0.1...25 A
0.1...25 A
0.1...16 A
UL, CSA
Demko, Semko
LRoS, BV
0.1...20 A
Approvals
16
32
2
11.5
1
3-pole
2-pole
1-pole
1
11.5
s
90
°
recess with panel thickness
s > 1.5 mm
3
11
12
24
Z
25
°
25
°
OFF
ON
1
1
19
43
6
3.5
1
6.8
6x6.8 = 40.8
polarizing tooth
30.5
18
37.5
25
12.5
11.5
12.5
12.5
blade terminals
DIN 46244-A6.3-0.8
50
32
mounting thread M3 or 6/32
max. screw length 5.8 mm
tightening torque 0.5 Nm
5
16
unit III
unit II
unit I
1
multi pole devices
1
23
2k
0
0
0
11
24 12
5
2
mounting area
(standard insulation)
operating area
(double insulation)
1
23
2k
Shock directions
OFF position
intermediate position ON position
Toggle positions
5
6
4
3
1
2
current rating