II CORE BLOCK: BCU (Bus Control Unit)
B-II-4-46
EPSON
S1C33T01 FUNCTION PART
A18EC: Areas 18–17 little/big endian method selection (D7) / Access control register (0x48132)
A16EC: Areas 16–15 little/big endian method selection (D6) / Access control register (0x48132)
A14EC: Areas 14–13 little/big endian method selection (D5) / Access control register (0x48132)
A12EC: Areas 12–11 little/big endian method selection (D4) / Access control register (0x48132)
A10EC: Areas 10–9 little/big endian method selection (D3) / Access control register (0x48132)
A8EC: Areas 8–7 little/big endian method selection (D2) / Access control register (0x48132)
A6EC: Area 6 little/big endian method selection (D1) / Access control register (0x48132)
A5EC: Areas 5–4 little/big endian method selection (D0) / Access control register (0x48132)
Select either little endian or big-endian method for accessing each area.
Write "1": Big-endian
Write "0": Little-endian
Read: Valid
When AxxEC is set to "1", the corresponding area is accessed in big-endian method. When AxxEC is set to "0", the
area is accessed in little-endian method. When using area 10 as the boot area, fix A10EC at "0" (little-endian).
At cold start, these bits are set to "0" (little-endian). At hot start, these bits retain their status before being initialized.
A18AS: Areas 18–17 address strobe signal (DF) / G/A read signal control register (0x48138)
A16AS: Areas 16–15 address strobe signal (DE) / G/A read signal control register (0x48138)
A14AS: Areas 14–13 address strobe signal (DD) / G/A read signal control register (0x48138)
A12AS: Areas 12–11 address strobe signal (DC) / G/A read signal control register (0x48138)
A8AS:
Areas 8–7 address strobe signal (DA) / G/A read signal control register (0x48138)
A6AS:
Area 6 address strobe signal (D9) / G/A read signal control register (0x48138)
A5AS:
Areas 5–4 address strobe signal (D8) / G/A read signal control register (0x48138)
Enable/disable the exclusive address strobe signal output.
Write "1": Enabled
Write "0": Disabled
Read: Valid
If AxxAS is set to "1", the exclusive address strobe signal is output from #GAAS (P21) pin when the corresponding
area is accessed. If AxxAS is set to "0", the signal output is disabled.
At cold start, these bits are set to "0" (disabled). At hot start, these bits retain their status before being initialized.
A18RD: Areas 18–17 read signal (D7) / G/A read signal control register (0x48138)
A16RD: Areas 16–15 read signal (D6) / G/A read signal control register (0x48138)
A14RD: Areas 14–13 read signal (D5) / G/A read signal control register (0x48138)
A12RD: Areas 12–11 read signal (D4) / G/A read signal control register (0x48138)
A8RD:
Areas 8–7 read signal (D2) / G/A read signal control register (0x48138)
A6RD:
Area 6 read signal (D1) / G/A read signal control register (0x48138)
A5RD:
Areas 5–4 read signal (D0) / G/A read signal control register (0x48138)
Enable/disable the exclusive read signal output.
Write "1": Enabled
Write "0": Disabled
Read: Valid
If AxxRD is set to "1", the exclusive read signal is output from #GARD (P31) pin when the corresponding area is
read. If AxxRD is set to "0", the signal output is disabled.
At cold start, these bits are set to "0" (disabled). At hot start, these bits retain their status before being initialized.
BCLKSEL1–BCLKSEL0: BCLK output clock selection (D[1:0]) / BCLK select register (0x4813A)
Select a clock to be output from the BCLK pin.
Table 4.32
Selection of BCLK Output Clock
BCLKSEL1
BCLKSEL0
Output clock
1
PLL_CLK (PLL output clock)
1
0
OSC3_CLK (OSC3 oscillation clock)
0
1
BCU_CLK (BCU operating clock)
0
CPU_CLK (CPU operating clock)