APPENDIX A LIST OF I/O REGISTERS
AP-A-24
Seiko Epson Corporation
S1C17705 TECHNICAL MANUAL
Register name Address
Bit
Name
Function
Setting
Init. R/W
Remarks
REMC Length
Counter Register
(REMC_LCNT)
0x5344
(16 bits)
D15–8 REMLEN[7:0] Transmit/receive data length count
(down counter)
0x0 to 0xff
0x0 R/W
D7–1 –
reserved
–
0 when being read.
D0
REMDT
Transmit/receive data
1 1 (H)
0 0 (L)
0
R/W
REMC Interrupt
Control Register
(REMC_INT)
0x5346
(16 bits)
D15–11 –
reserved
–
0 when being read.
D10
REMFIF
Falling edge interrupt flag
1 Cause of
interrupt
occurred
0 Cause of
interrupt not
occurred
0
R/W Reset by writing 1.
D9
REMRIF
Rising edge interrupt flag
0
R/W
D8
REMUIF
Underflow interrupt flag
0
R/W
D7–3 –
reserved
–
0 when being read.
D2
REMFIE
Falling edge interrupt enable
1 Enable
0 Disable
0
R/W
D1
REMRIE
Rising edge interrupt enable
1 Enable
0 Disable
0
R/W
D0
REMUIE
Underflow interrupt enable
1 Enable
0 Disable
0
R/W
0x5380–0x5386
A/D Converter
Register name Address
Bit
Name
Function
Setting
Init. R/W
Remarks
A/D Conversion
Result Register
(ADC10_ADD)
0x5380
(16 bits)
D15–0 ADD[15:0] A/D converted data
ADD[9:0] are effective when
STMD = 0 (ADD[15:10] = 0)
ADD[15:6] are effective when
STMD = 1 (ADD[5:0] = 0)
0x0 to 0x3ff
0x0
R
A/D Trigger/
Channel Select
Register
(ADC10_TRG)
0x5382
(16 bits)
D15–14 –
reserved
–
0 when being read.
D13–11 ADCE[2:0] End channel select
0x0 to 0x7
0x0 R/W
D10–8 ADCS[2:0] Start channel select
0x0 to 0x7
0x0 R/W
D7
STMD
Conversion result storing mode
1 ADD[15:6]
0 ADD[9:0]
0
R/W
D6
ADMS
Conversion mode select
1 Continuous 0 Single
0
R/W
D5–4 ADTS[1:0] Conversion trigger select
ADTS[1:0]
Trigger
0x0 R/W
0x3
0x2
0x1
0x0
#ADTRG pin
reserved
T16 Ch.0
Software
D3
–
reserved
–
0 when being read.
D2–0 ADST[2:0] Sampling time setting
ADST[2:0]
Sampling time 0x7 R/W
0x7
0x6
0x5
0x4
0x3
0x2
0x1
0x0
9 cycles
8 cycles
7 cycles
6 cycles
5 cycles
4 cycles
3 cycles
2 cycles
A/D Control/
Status Register
(ADC10_CTL)
0x5384
(16 bits)
D15
–
reserved
–
0 when being read.
D14–12 ADICH[2:0] Conversion channel indicator
0x0 to 0x7
0x0
R
D11
–
reserved
–
0 when being read.
D10
ADIBS
ADC10 status
1 Busy
0 Idle
0
R
D9
ADOWE
Overwrite error flag
1 Error
0 Normal
0
R/W Reset by writing 1.
D8
ADCF
Conversion completion flag
1 Completed 0 Run/Stand-
by
0
R Reset when ADC10_
ADD is read.
D7–6 –
reserved
–
0 when being read.
D5
ADOIE
Overwrite interrupt enable
1 Enable
0 Disable
0
R/W
D4
ADCIE
Conversion completion int. enable 1 Enable
0 Disable
0
R/W
D3–2 –
reserved
–
0 when being read.
D1
ADCTL
A/D conversion control
1 Start
0 Stop
0
R/W
D0
ADEN
ADC10 enable
1 Enable
0 Disable
0
R/W
A/D Clock
Control Register
(ADC10_CLK)
0x5386
(16 bits)
D15–4 –
reserved
–
0 when being read.
D3–0 ADDF[3:0] A/D converter clock division ratio
select
ADDF[3:0]
Division ratio
0x0 R/W Source clock = PCLK
0xf
0xe
0xd
0xc
0xb
0xa
0x9
0x8
0x7
0x6
0x5
0x4
0x3
0x2
0x1
0x0
reserved
1/32768
1/16384
1/8192
1/4096
1/2048
1/1024
1/512
1/256
1/128
1/64
1/32
1/16
1/8
1/4
1/2