參數(shù)資料
型號: PCL6045B
廠商: Electronic Theatre Controls, Inc.
英文描述: User Manual For PCL6045B Pulse Control LSI
中文描述: 用戶手冊PCL6045B脈沖控制大規(guī)模集成電路
文件頁數(shù): 73/176頁
文件大?。?/td> 7952K
代理商: PCL6045B
-
66
-
9-5-1.
Zero
return
operation
After
writing
a
start
command,
the
axis
will
continue
feeding
until
the
conditions
for
a
zero
return
complete
are
satisfied.
MOD:
10h
Positive
direction
zero
return
operation
18h
Negative
direction
zero
return
operation
When
a
zero
return
is
complete,
the
LSI
will
reset
the
counter
and
output
an
ERC
(deflection
counter
clear)
signal.
The
RENV3
register
is
used
to
set
the
basic
zero
return
method.
That
is,
whether
or
not
to
reset
the
counter
when
the
zero
return
is
complete.
Specify
whether
or
not
to
output
the
ERC
signal
in
the
RENV1
register.
For
details
about
the
ERC
signal,
see
11-6-2,
"ERC
signal."
Set
the
zero
return
method
<Set
ORM0
to
3
(bits
0
to
3)
in
RENV3>
0000:
Zero
return
operation
0
-
Stop
immediately
(deceleration
stop
when
feeding
at
high
speed)
when
the
ORG
signal
turns
ON
-
COUNTER
reset
timing:
When
the
ORG
input
signal
turns
ON.
0001:
Zero
return
operation
1
-
Stop
immediately
(deceleration
stop
when
feeding
at
high
speed)
when
the
ORG
signal
turns
ON.
Next,
feed
in
the
reverse
direction
at
RFA
low
speed
until
the
ORG
signal
turns
OFF.
Then,
the
axis
moves
back
in
the
original
direction
at
RFA
speed
and
stops
immediately
when
ORG
turns
ON
again.
-
COUNTER
reset
timing:
When
the
ORG
input
signal
turns
ON.
0010:
Zero
return
operation
2
-
When
feeding
at
low
speed,
after
the
ORG
signal
turns
ON,
movement
on
the
axis
stops
immediately
when
the
EZ
counter
finishes
counting
up.
When
feeding
at
high
speed,
after
the
ORG
signal
turns
ON,
the
axis
decelerates
and
stops
immediately
when
the
EZ
counter
finishes
counting
up.
-
COUNTER
reset
timing:
When
the
EZ
counter
finishes
counting
up.
0011:
Zero
return
operation
3
-
When
feeding
at
low
speed,
after
the
ORG
signal
turns
ON,
movement
on
the
axis
stops
immediately
when
the
EZ
counter
finishes
counting
up.
When
feeding
at
high
speed,
after
the
ORG
signal
turns
ON,
the
axis
decelerates
and
stops
immediately
when
the
EZ
counter
finishes
counting
up.
-
COUNTER
reset
timing:
When
the
EZ
counter
finishes
counting
up.
0100:
Zero
return
operation
4
-
Movement
on
the
axis
stops
immediately
(decelerate
and
stop
when
feeding
at
high
speed)
when
the
ORG
input
is
turned
ON.
Next,
the
direction
of
movement
is
reversed
at
RFA
low
speed.
Then,
it
stops
immediately
when
the
EZ
counter
finishes
counting
up.
-
COUNTER
reset
timing:
When
the
EZ
counter
finishes
counting
up.
[RENV3]
(WRITE)
7
-
-
-
-
n
n
n
n
0
相關(guān)PDF資料
PDF描述
PCLR20014-SERIES Optoelectronic
PCA200A2 Optoelectronic
PCA200G2 Optoelectronic
PCA200O2 Optoelectronic
PCA200R2 Optoelectronic
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
PCL6605 制造商:Tamura Corporation of America 功能描述:
PCL6610 制造商:Tamura Corporation of America 功能描述:
PCL6611 制造商:Tamura Corporation of America 功能描述:
PCL6630 制造商:Tamura Corporation of America 功能描述: