參數(shù)資料
型號: PCL6045B
廠商: Electronic Theatre Controls, Inc.
英文描述: User Manual For PCL6045B Pulse Control LSI
中文描述: 用戶手冊PCL6045B脈沖控制大規(guī)模集成電路
文件頁數(shù): 68/176頁
文件大?。?/td> 7952K
代理商: PCL6045B
-
61
-
9-3-1.
Continuous
operation
using
a
pulsar
input
(MOD:
01h)
This
mode
allows
continuous
operation
using
a
pulsar
input.
When
PA/PB
signals
are
input
after
writing
a
start
command,
the
LSI
will
output
pulses
to
the
OUT
terminal.
The
feed
direction
depends
on
PA/PB
signal
input
method
and
the
value
set
in
PDIR.
PA/PB
input
method
PDIR
Feed
direction
Positive
direction
0
Negative
direction
Positive
direction
(1x,
2x,
and
4x)
1
Negative
direction
Positive
direction
0
Negative
direction
Positive
direction
negative
pulses
1
Negative
direction
PA/PB
input
When
the
PA
phase
leads
the
PB
phase.
When
the
PB
phase
leads
the
PA
phase.
When
the
PB
phase
leads
the
PA
phase.
When
the
PA
phase
leads
the
PB
phase.
PA
input
rising
edge.
PB
input
rising
edge.
PB
input
rising
edge.
PA
input
rising
edge.
90
phase difference
signal
2
pulse
input
of
positive
and
The
PCL
stops
operation
when
the
EL
signal
in
the
current
feed
direction
is
turned
ON.
But
the
PCL
can
be
operated
in
the
opposite
direction
without
writing
a
restart
command.
When
stopped
by
the
EL
input,
no
error
interrupt
(
To
release
the
operation
mode,
write
an
immediate
stop
command
(49h).
output)
will
occur.
Note:
When
the
"immediate
stop
command
(49h)"
is
written
while
the
PCL
is
performing
a
multiplication
operation
(caused
by
setting
PIM
0
to
1
and
PMG
0
to
4),
the
PCL
will
stop
operation
immediately
and
the
total
number
of
pulses
that
are
output
will
not
be
an
even
multiple
of
the
magnification.
When
PSTP
in
RENV6
is
set
to
1,
the
PCL
delays
the
stop
timing
until
an
even
multiple
of
pulses
has
been
output.
However,
after
a
stop
command
is
sent
by
setting
PSTP
to
1,
check
the
MSTS.
If
SRUN
is
0,
set
PSTP
to
0.
(When
SRUN
is
0
while
PSTP
is
1,
the
PCL
will
latch
the
stop
command.)
9-3-2.
Positioning
operations
using
a
pulsar
input
(MOD:
51h)
The
PCL
positioning
is
synchronized
with
the
pulsar
input
by
using
the
PRMV
setting
as
incremental
position
data.
This
mode
allows
positioning
using
a
pulsar
input.
The
feed
direction
is
determined
by
the
sign
in
the
PMV
register.
When
PA/PB
signals
are
input,
the
LSI
outputs
pulses
and
the
positioning
counter
counts
down.
When
the
value
in
the
positioning
counter
reaches
zero,
movement
on
the
axis
will
stop
and
another
PA/
PB
input
will
be
ignored.
Set
the
RMV
register
value
to
zero
and
start
the
positioning
operation.
The
LSI
will
stop
movement
on
the
axis
immediately,
without
outputting
any
command
pulses.
9- - .
Position
op r t n
s
a
pu r
i pu
( ec
absolute
os
to
OUNT R1)
(MOD:
2h)
The
PCL
positioning
is
synchronized
with
the
pulsar
input
by
using
the
PRMV
setting
as
the
absolute
value
for
COUNTER1.
The
direction
of
movement
is
determined
by
the
relationship
between
the
value
in
PRMV
and
the
value
in
COUNTER1.
When
starting,
the
difference
between
the
values
in
RMV
and
COUNTER1
is
loaded
into
the
positioning
counter.
When
a
PA/PB
signal
is
input,
the
PCL
outputs
pulses
and
decrements
the
positioning
counter.
When
the
value
in
the
positioning
counter
reaches
"0,"
the
PCL
any
further
ignores
PA/PB
input.
If
you
try
to
start
with
PRMV
=
COUNTER1,
the
PCL
will
not
output
any
pulses
and
it
will
stop
immediately.
9- - .
Position
op r t n
s
a
pu r
i pu
( ec
the
absolute
os
in
COUNT R2)
(MOD:
53 )
The
operation
procedures
are
the
same
as
MOD=
52h,
except
that
this
function
uses
COUNTER2
instead
of
COUNTER1.
相關(guān)PDF資料
PDF描述
PCLR20014-SERIES Optoelectronic
PCA200A2 Optoelectronic
PCA200G2 Optoelectronic
PCA200O2 Optoelectronic
PCA200R2 Optoelectronic
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
PCL6605 制造商:Tamura Corporation of America 功能描述:
PCL6610 制造商:Tamura Corporation of America 功能描述:
PCL6611 制造商:Tamura Corporation of America 功能描述:
PCL6630 制造商:Tamura Corporation of America 功能描述:
PCL-711B 制造商:ADVANTECH 制造商全稱:Advantech Co., Ltd. 功能描述:40 kS/s, 12-bit, 8-ch SE Input ISA Multifunction Card