Am79C965A
155
14
LEDPOL LED Polarity. When this bit has the
value ZERO, then the LED pin will
be driven to a LOW level whenever
the OR of the enabled signals is true
and the LED pin will be floated and
allowed to float high whenever the
OR of the enabled signals is false
(i.e. the LED output will be an Open
Drain output and the output value
will be the inverse of the LEDOUT
status bit).
When this bit has the value ONE,
then the LED pin will be driven to a
HIGH level whenever the OR of the
enabled signals is true and the LED
pin will be driven to a LOW level
whenever the OR of the enabled
signals is false (i.e. the LED output
will be a Totem Pole output and the
output value will be the same
polarity as the LEDOUT status bit).
The setting of this bit will not affect
the polarity of the LEDOUT bit for
this register.
13
LEDDIS
LED Disable. This bit is used to
disable the LED output. When
LEDDIS has the value ONE, then
the LED output will always be
floated. When LEDDIS has the
value ZERO, then the LED output
value will be governed by the
LEDOUT and LEDPOL values.
12-8
RES
Reserved locations. Written as
ZEROs, read as undefined.
7
PSE
Pulse Stretcher Enable. Extends the
LED illumination time for each new
occurrence of the enabled function
for this LED output.
A value of 0 disables the function. A
value of 1 enables the function.
6
LNKSTE Link Status Enable. Indicates the
current link status on the Twisted
Pair interface. When this bit is set, a
value of ONE will be passed to the
LEDOUT signal to indicate that the
link status state is PASS. A value of
ZERO will be passed to the
LEDOUT signal to indicate that the
link status state is FAIL.
A value of 0 disables the signal. A
value of 1 enables the signal.
5
RCVME
Receive
Indicates receive activity on the
Match
status
Enable.
network that has passed the ad-
dress match function for this node.
All address matching modes are
included: Physical, Logical filtering,
Promiscuous, Broadcast, and EADI.
A value of 0 disables the signal. A
value of 1 enables the signal.
4
XMTE
Transmit status Enable. Indicates
PCnet-32 controller transmit activity.
A value of 0 disables the signal. A
value of 1 enables the signal.
3
RXPOLE Receive Polarity status Enable.
Indicates the current Receive
Polarity condition on the Twisted
Pair interface. A value of ONE
indicates that the polarity of the
RXD± pair has been reversed. A
value of ZERO indicates that the
polarity of the RXD± pair has not
been reversed.
Receive polarity indication is valid
only if the LNKST bit of BCR4
indicates link PASS status.
A value of 0 disables the signal. A
value of 1 enables the signal.
2
RCVE
Receive status Enable. Indicates
receive activity on the network.
A value of 0 disables the signal. A
value of 1 enables the signal.
1
JABE
Jabber status Enable. Indicates that
the PCnet-32 controller is jabbering
on the network.
A value of 0 disables the signal. A
value of 1 enables the signal.
0
COLE
Collision status Enable. Indicates
collision activity on the network.
When the AUI port is selected,
collision activity during the 4.0 ms
internal following a transmit
completion (SQE internal) will not
activate the LEDOUT bit.
A value of 0 disables the signal. A
value of 1 enables the signal.
BCR5: LED1 Status
Bit
Name
Description
BCR5 controls the function(s) that
the LED1 pin displays. Multiple
functions can be simultaneously
enabled on this LED pin. The LED
display will indicate the logical OR of