CHAPTER 13 A/D CONVERTER
User’s Manual U17790EJ2V0UD
477
13.5 Operation
13.5.1 Basic operation
<1> Set the operation mode, trigger mode, and conversion time for executing A/D conversion by using the
ADA0M0, ADA0M1, ADA0M2, and ADA0S registers. When the ADA0CE bit of the ADA0M0 register is set,
conversion is started in the software trigger mode and the A/D converter waits for a trigger in the external or
timer trigger mode.
<2> When A/D conversion is started, the voltage input to the selected analog input channel is sampled by the
sample & hold circuit.
<3> When the sample & hold circuit samples the input channel for a specific time, it enters the hold status, and
holds the input analog voltage until A/D conversion is complete.
<4> Set bit 9 of the successive approximation register (SAR) to set the compare voltage generation DAC to (1/2)
AVREF0.
<5> The voltage difference between the compare voltage generation DAC and the analog input voltage is
compared by the voltage comparator. If the analog input voltage is higher than (1/2) AVREF0, the MSB of the
SAR register remains set. If it is lower than (1/2) AVREF0, the MSB is reset.
<6> Next, bit 8 of the SAR register is automatically set and the next comparison is started. Depending on the
value of bit 9, to which a result has been already set, the compare voltage generation DAC is selected as
follows.
Bit 9 = 1: (3/4) AVREF0
Bit 9 = 0: (1/4) AVREF0
This compare voltage and the analog input voltage are compared and, depending on the result, bit 8 is
manipulated as follows.
Analog input voltage
≥ Compare voltage: Bit 8 = 1
Analog input voltage
≤ Compare voltage: Bit 8 = 0
<7> This comparison is continued to bit 0 of the SAR register.
<8> When comparison of the 10 bits is complete, the valid digital result is stored in the SAR register, which is then
transferred to and stored in the ADA0CRn register. After that, an A/D conversion end interrupt request signal
(INTAD) is generated.
<9> In one-shot select mode, conversion is stopped
Note. In one-shot scan mode, conversion is stopped after
scanning once
Note. In continuous select mode, repeat steps <2> to <8> until the ADA0M0.ADA0CE bit is
cleared to 0. In continuous scan mode, repeat steps <2> to <8> for each channel.
Note In the external trigger mode, timer trigger mode 0, or timer trigger mode 1, the trigger standby status
is entered.
Remark
The trigger standby status means the status after the stabilization time has elapsed.