5 PERIPHERAL CIRCUITS AND THEIR OPERATION (Interrupt and Standby Status)
5.14.2 Interrupt factor flag
Table 5.14.2.1 shows the correspondence between
the factors generating an interrupt and the inter-
rupt factor flags.
The corresponding interrupt factor flags are set to
"1" by generation of the respective interrupt factors.
The corresponding interrupt factor can be con-
firmed by reading the flags through software.
Interrupt factor flag that has been set to "1" is reset
to "0" by writing "1".
At initial reset, the interrupt factor flags are reset to "0".
Note: When executing the RETE instruction
without resetting the interrupt factor flag after
an interrupt has been generated, the same
interrupt will be generated. Consequently,
the interrupt factor flag corresponding to that
routine must be reset (writing "1") in the
interrupt processing routine.
Table 5.14.2.1 Interrupt factors
K07 input of falling edge or rising edge (instruction at KCP07)
K06 input of falling edge or rising edge (instruction at KCP06)
K05 input of falling edge or rising edge (instruction at KCP05)
K04 input of falling edge or rising edge (instruction at KCP04)
K03 input of falling edge or rising edge (instruction at KCP03)
K02 input of falling edge or rising edge (instruction at KCP02)
K01 input of falling edge or rising edge (instruction at KCP01)
K00 input of falling edge or rising edge (instruction at KCP00)
Programmable timer 0 underflow
Programmable timer 0 compare match
Programmable timer 1 underflow
Programmable timer 1 compare match
Programmable timer 2 underflow
Programmable timer 2 compare match
Programmable timer 3 underflow
Programmable timer 3 compare match
Programmable timer 4 underflow
Programmable timer 4 compare match
Programmable timer 5 underflow
Programmable timer 5 compare match
Programmable timer 6 underflow
Programmable timer 6 compare match
Programmable timer 7 underflow
Programmable timer 7 compare match
Serial interface 0 receiving error (in asynchronous mode)
Serial interface 0 receiving completion
Serial interface 0 transmitting completion
Serial interface 1 receiving error (in asynchronous mode)
Serial interface 1 receiving completion
Serial interface 1 transmitting completion
Falling edge of the stopwatch timer 100 Hz signal
Falling edge of the stopwatch timer 10 Hz signal
Falling edge of the stopwatch timer 1 Hz signal
Falling edge of the clock timer 32 Hz signal
Falling edge of the clock timer 8 Hz signal
Falling edge of the clock timer 2 Hz signal
Falling edge of the clock timer 1 Hz signal
Interrupt factor flag
Interrupt factor
FK07
FK06
FK05
FK04
FK03
FK02
FK01
FK00
FTU0
FTC0
FTU1
FTC1
FTU2
FTC2
FTU3
FTC3
FTU4
FTC4
FTU5
FTC5
FTU6
FTC6
FTU7
FTC7
FSERR0
FSREC0
FSTRA0
FSERR1
FSREC1
FSTRA1
FSW100
FSW10
FSW1
FTM32
FTM8
FTM2
FTM1
00FF28HD7
00FF28HD6
00FF28HD5
00FF28HD4
00FF28HD3
00FF28HD2
00FF28HD1
00FF28HD0
00FF29HD0
00FF29HD1
00FF29HD2
00FF29HD3
00FF29HD4
00FF29HD5
00FF29HD6
00FF29HD7
00FF2EHD0
00FF2EHD1
00FF2EHD2
00FF2EHD3
00FF2EHD4
00FF2EHD5
00FF2EHD6
00FF2EHD7
00FF27HD2
00FF27HD1
00FF27HD0
00FF27HD5
00FF27HD4
00FF27HD3
00FF26HD6
00FF26HD5
00FF26HD4
00FF26HD3
00FF26HD2
00FF26HD1
00FF26HD0