MOTOROLA
Chapter 10. Memory Controller
10-27
Part III. The Hardware Interface
Table 10-9 describes M
x
MR bits.
Table 10-9. Machine x Mode Registers (MxMR)
Bits
Name
Description
0
BSEL
Bus select. Assigns banks that select UPMxto the 60x or local bus.
0 Banks that select UPMx are assigned to the 60x bus.
1 Banks that select UPMx are assigned to the local bus.
Note: if refresh is required, the UPM’s should be assigned as follows:
UPMA: 60x bus (if 60x bus refresh needed)
UPMB: Local bus (if local bus refresh required)
UPMC: any bus, as long as UPMA or UPMB is used on the relevant bus.
See Section 10.6.1.2, “UPM Refresh Timer Requests.”
1
RFEN
Refresh enable. Indicates that the UPM needs refresh services.
0 Refresh services are not required
1 Refresh services are required
See Section 10.3.8, “60x Bus-Assigned UPM Refresh Timer (PURT),” Section 10.3.9, “Local
Bus-Assigned UPM Refresh Timer (LURT),” Section 10.3.10, “60x Bus-Assigned SDRAM
Refresh Timer (PSRT),” and Section 10.3.11, “Local Bus-Assigned SDRAM Refresh Timer
(LSRT).”
2–3
OP
Command opcode. Determines the command executed by the UPMx when a memory access
hit a UPM assigned bank.
00 Normal operation.
01 Write to array. On the next memory access that hits a UPM assigned bank, write the
contents of the MDR into the RAM location pointed by MAD. After the access, the MAD field
is automatically incremented.
10 Read from array. On the next memory access that hits a UPM assigned bank, read the
contents of the RAM location pointed by MAD into the MDR. After the access, the MAD field
is automatically incremented
11 Run pattern. On the next memory access that hits a UPM assigned bank, run the pattern
written in the RAM array. The pattern run starts at the location pointed by MAD and
continues until the LAST bit is set in the RAM.
Note: RLF determines the number of times a loop is executed during a pattern run.
4
—
Reserved, should be cleared.
5–7
AMx
Address multiplex size. Determines how the address of the current memory cycle can be output
on the address pins. The address output on the pins controlled by the contents of the UPMx
RAM array. This field is useful when connecting the MPC8260 to DRAM devices requiring row
and column addresses multiplexed on the same pins.
See Section 10.6.4.2, “Address Multiplexing.”
8–9
DSx
Disable timer period. Guarantees a minimum time between accesses to the same memory bank
if it is controlled by the UPMx. The disable timer is turned on by the TODT in the RAM array, and
when expired, the UPMx allows the machine access to handle a memory pattern to the same
memory region. Accesses to a different memory region by the same UPMx will be allowed.
00 1-cycle disable period
01 2-cycle disable period
10 3-cycle disable period
11 4-cycle disable period
Note: To avoid conflicts between successive accesses to different memory regions, the
minimum pattern in the RAM array for a request serviced should not be shorter than the period
established by DSx