MD8412B
28
FUJIFUILM MICRODEVICES CO., LTD.
Ver 1.10
This bit is used for transmission in IsoMode in cases other than 11bM It is also used for reception in the
case of "011b". It indicates that the isochronous buffer being accessed from the ITF/IRF Data register is full.
Bit 6
IRFEmpty
: IRF Empty bit (R- Initial value: 1b)
= Indicating a condition that the buffer is not empty
= Indicating a condition that the buffer is empty
0
1
Bit 12
DreqEn
: Dreq Enable bit (RW- Initial value: 0b)
= DREQ signal is left non-active at any time
= DREQ signal is turned active as the status of contents chosen by SelectDreq.
This bit is intended to make the DREQ signal valid.
0
1
Bit 14~13
SelectDreq
: Select Dreq bit (RW- Initial value: 00b)
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ATFFull bit for
the buffer being accessed by the ATF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ATFEmpty bit for
the buffer being accessed by the ATF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ITFFull bit in the
transmission mode and that of IRFEmpty bit in the reception mode, for the buffer being accessed by
the ITF/IRF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the IRFEmpty bit for
the buffer being accessed by the IRF Data register.
This register is used to determine what buffer status in the chip should be reflected on the DREQ signal.
00
01
10
11
Bit 24~16
IRFcount
: IRF count bit (R- Initial value: 00b)
This bit is used to indicate the data size in the Quadlet unit, stored in the buffer (IRF or ITF/IRF) chosen by
the SelectDreq bit in the auto-mode. Invalid if SelectDreq is 00,01.
If the first setting is made for SelectDreq or it is modified after the power supply has been turned on, it is nec-
essary to follow the procedures specified below, in order to read out the IRFcount data.
1. Set at DreqEn = "0"
2. SelectDreq is set for the required FIFO type.
3. After the completion of the above-mentioned setting, the data size stored in the required FIFO can be
read from the IRFcount.