參數(shù)資料
型號: MD8412B
廠商: Electronic Theatre Controls, Inc.
英文描述: LINK(IEEE 1394)
中文描述: 鏈接(1394)
文件頁數(shù): 40/114頁
文件大小: 577K
代理商: MD8412B
MD8412B
28
FUJIFUILM MICRODEVICES CO., LTD.
Ver 1.10
This bit is used for transmission in IsoMode in cases other than 11bM It is also used for reception in the
case of "011b". It indicates that the isochronous buffer being accessed from the ITF/IRF Data register is full.
Bit 6
IRFEmpty
: IRF Empty bit (R- Initial value: 1b)
= Indicating a condition that the buffer is not empty
= Indicating a condition that the buffer is empty
0
1
Bit 12
DreqEn
: Dreq Enable bit (RW- Initial value: 0b)
= DREQ signal is left non-active at any time
= DREQ signal is turned active as the status of contents chosen by SelectDreq.
This bit is intended to make the DREQ signal valid.
0
1
Bit 14~13
SelectDreq
: Select Dreq bit (RW- Initial value: 00b)
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ATFFull bit for
the buffer being accessed by the ATF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ATFEmpty bit for
the buffer being accessed by the ATF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the ITFFull bit in the
transmission mode and that of IRFEmpty bit in the reception mode, for the buffer being accessed by
the ITF/IRF Data register.
= This bit is reflected on the DREQ signal as the status being equivalent to that of the IRFEmpty bit for
the buffer being accessed by the IRF Data register.
This register is used to determine what buffer status in the chip should be reflected on the DREQ signal.
00
01
10
11
Bit 24~16
IRFcount
: IRF count bit (R- Initial value: 00b)
This bit is used to indicate the data size in the Quadlet unit, stored in the buffer (IRF or ITF/IRF) chosen by
the SelectDreq bit in the auto-mode. Invalid if SelectDreq is 00,01.
If the first setting is made for SelectDreq or it is modified after the power supply has been turned on, it is nec-
essary to follow the procedures specified below, in order to read out the IRFcount data.
1. Set at DreqEn = "0"
2. SelectDreq is set for the required FIFO type.
3. After the completion of the above-mentioned setting, the data size stored in the required FIFO can be
read from the IRFcount.
相關PDF資料
PDF描述
MDC3105LT1 RELAY/SOLENOID DRIVER SILICON MONOLITHIC CIRCUIT BLOCK
MEGA128CAN Microcontroller WITH 128K BYTES OF ISP FLASH AND CAN CONTROLLER
MF-10KDS-R13-060 CAP 50UF 5.5V +80-20% SUPERCAP PLANAR-MT ULTRA-LOWESR HIGH-PWR
MF-10KDS-R13-061 CAPACITOR, BESTCAP 30 MILLI FARAD 5.5V CAPACITOR, BESTCAP 30 MILLI FARAD 5.5V; CAPACITANCE:30MF; VOLTAGE RATING, DC:5.5V; CAPACITOR DIELECTRIC TYPE:ELECTRONIC; SERIES:BESTCAP; TEMP, OP. MAX:70(DEGREE C); TEMP, OP. MIN:-20(DEGREE C); RoHS Compliant: Yes
MF-10KDS-R13-070 CAP 60UF 5.5V +80-20% SUPERCAP THRUHOLE ULTRA-LOWESR HIGH-PWR
相關代理商/技術參數(shù)
參數(shù)描述
MD8451H-8/B 制造商:undefined 功能描述:
MD845A-R2 制造商:Black Box Corporation 功能描述:MODEM 202
MD845A-R2-W1 制造商:Black Box Corporation 功能描述:1 YEAR WARRANTY FOR MD845A-R2
MD845A-R2-W3 制造商:Black Box Corporation 功能描述:3 YEAR WARRANTY FOR MD845A-R2
MD8748H 制造商: 功能描述: 制造商:undefined 功能描述: