第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)當(dāng)前第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)
Intelligent Eight-Channel Communications Controller
CD1865
Datasheet
35
5.4.2
Transmit Service Requests
Each transmitter contains 8 bytes of Transmit FIFO in addition to the Transmit Holding register
and the Transmit Shift register. As data is being transmitted, the FIFO status is being monitored by
the CD1865. A service request is invoked for one of the following conditions:
Transmit FIFO Empty
When the Transmit FIFO is empty, there is still one character in the
Transmit Holding register and one character in the Transmit Shift register. The host has two
character times to respond to this request without causing a gap in the Transmit Data Stream.
Transmitter Empty
The Transmit FIFO, Transmit Holding register, and the Transmit Shift
registers are now empty. This signifies that all characters written to the FIFO are completely
transmitted.
The host can select which one of these causes a Transmit Service Request, and it is used by
programming the options in the Service Request Enable register (SRER).
Data must
not
be put into the Transmit FIFO at any time other than when the CD1865 is in a
Transmit Service Request context for that channel. During a transmit service, characters (up to
eight) are placed into the FIFO by the Transmit Data register (TDR).
5.4.3
Modem Signal Change Service Requests
The CD1865 can be programmed to assert a service request when a channel
s modem input signals
has changed states. The change-detect options are programmed in the Modem Change Option
registers. Individual modem pin service requests are enabled by setting the corresponding bits in
the Service Request Enable register.
The host must read the Modem Change register during a modem change service to determine
which modem signal changes were detected. This is indicated by a
1
in the appropriate bit
location. The Modem Change register must be reset to a
0
by the host before exiting the service
request because the CD1865 does not do this. Refer to
Section 7.4
for more details.
5.4.3.1
Using Modem Pins as Input/Output
The pins labelled as modem pins are general-purpose I/O pins that can be controlled by either the
CD1865 processor or the host system. There is no direct, hardwired connection from any modem
pin directly to a transmitter or a receiver. This means that these pins can be used for general-
purpose I/O if they are not needed for modem-control purposes. See
Section 7.4
for more details.
5.5
Implementing Service Requests
The CD1865 is designed to easily interface with any processor, yet be efficient and flexible enough
to provide maximum throughput. The CD1865 generates service requests and waits for
acknowledgments of these from the host. However, service requests can be implemented in either
hardware or software; likewise, acknowledgments can be affected either way to offer maximum
advantages to the system designer and programmer. This interfacing can be grouped as various
steps.
Service requests must be
noticed
by the host system before they can be acted on, and this can be
done the following three ways:
相關(guān)PDF資料
PDF描述
CD22100 CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22100E CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22100F CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22101 CMOS 4 x 4 x 2 Crosspoint Switch with Control Memory
CD22101E CMOS 4 x 4 x 2 Crosspoint Switch with Control Memory
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CD1865N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1865P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1866N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1866P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1867N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC