參數(shù)資料
型號(hào): FDC37C666GT
廠(chǎng)商: STANDARD MICROSYSTEMS CORP
元件分類(lèi): 存儲(chǔ)控制器/管理單元
英文描述: High-Performance Multi-Mode Parallel Port Super I/O Floppy Disk Controllers
中文描述: 1 Mbps, IDE COMPATIBLE, FLOPPY DISK DRIVE CONTROLLER, PQFP100
封裝: QFP-100
文件頁(yè)數(shù): 66/152頁(yè)
文件大?。?/td> 621K
代理商: FDC37C666GT
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)當(dāng)前第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)
66
Definition of DTL when N = 0 and when N
does not = 0
Write Deleted Data
This command is almost the same as the Write
Data command except that a Deleted Data
Address Mark is written at the beginning of the
Data Field instead of the normal Data Address
Mark. This command is typically used to mark
a bad sector containing an error on the floppy
disk.
Verify
The Verify command is used to verify the data
stored on a disk. This command acts exactly
like a Read Data command except that no data
is transferred to the host. Data is read from the
disk and CRC is computed and checked against
the previously-stored value.
Because data is not transferred to the host, TC
(pin 35) cannot be used to terminate this
command. By setting the EC bit to "1", an
implicit TC will be issued to the FDC. This
implicit TC will occur when the SC value has
decremented to 0 (an SC value of 0 will verify
256 sectors). This command can also be
terminated by setting the EC bit to "0" and the
EOT value equal to the final sector to be
checked. If EC is set to "0", DTL/SC should be
programmed to 0FFH. Refer to Table 27 and
Table 28 for information concerning the values
of MT and EC versus SC and EOT value.
Definitions:
# Sectors Per Side = Number of formatted
sectors per each side of the disk.
# Sectors Remaining = Number of formatted
sectors left which can be read, including side 1
of the disk if MT is set to "1".
Table 28 - Verify Command Result Phase Table
SC/EOT VALUE
MT
EC
TERMINATION RESULT
0
0
SC = DTL
EOT
# Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
Success Termination
Result Phase Valid
0
0
Unsuccessful Termination
Result Phase Invalid
0
1
SC
# Sectors Remaining AND
EOT
# Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
Successful Termination
Result Phase Valid
0
1
Unsuccessful Termination
Result Phase Invalid
1
0
SC = DTL
EOT
# Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
Successful Termination
Result Phase Valid
1
0
Unsuccessful Termination
Result Phase Invalid
1
1
SC
# Sectors Remaining AND
EOT
# Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
Successful Termination
Result Phase Valid
1
1
Unsuccessful Termination
Result Phase Invalid
相關(guān)PDF資料
PDF描述
FDC37C67X ENHANCED SUPER I/O CONTROLLER WITH FAST IR
FDC37C957FR ULTRA I/O CONTROLLER FOR PORTABLE APPLICATIONS
FDC37M600 ENHANCED SUPER I/O CONTROLLER WITH INFRARED SUPPORT
FDC37M601 ENHANCED SUPER I/O CONTROLLER WITH INFRARED SUPPORT
FDC37M602 ENHANCED SUPER I/O CONTROLLER WITH INFRARED SUPPORT
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
FDC37C669 制造商:SMSC 制造商全稱(chēng):SMSC 功能描述:PC 98/99 Compliant Super I/O Floppy Disk Controller with Infrared Support
FDC37C669_07 制造商:SMSC 制造商全稱(chēng):SMSC 功能描述:PC 98/99 Compliant Super I/O Floppy Disk Controller with Infrared Support
FDC37C669FRQFP 制造商:Rochester Electronics LLC 功能描述:- Bulk
FDC37C669FRTQFP 制造商:Rochester Electronics LLC 功能描述:- Bulk
FDC37C669-MS 功能描述:輸入/輸出控制器接口集成電路 Super I/O Controller- Pb Free RoHS:否 制造商:Silicon Labs 產(chǎn)品: 輸入/輸出端數(shù)量: 工作電源電壓: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:QFN-64 封裝:Tray