DS3161/DS3162/DS3163/DS3164
Figure 10-39. DS3 Subframe Framer State Diagram
Sync
Load
Verify
All 4 bit positions failed
2 F-bits loaded
3
bi
t p
os
iti
on
s
fa
ile
d
or
16
F-
bi
ts
ve
rif
ie
d
A
ll
4
bit
po
siti
on
s
fai
led
The multiframe framer checks for a multiframe boundary. When the multiframe framer identifies a multiframe
boundary, it updates the data path frame counters if either an OOF or OOMF condition is present. The multiframe
framer waits until a subframe boundary has been identified. Then, each bit position is checked for the multiframe
boundary. The multiframe boundary is found by identifying the three multiframe alignment bits (M-bits). Since there
are seven multiframe bits and three bits are required to identify the multiframe boundary, up to 9 checks may be
needed to find the multiframe boundary. Once the multiframe boundary is identified, it is checked in each
subsequent frame. The data path frame counters are updated if the three multiframe alignment bits are error free,
and an OOF or OOMF condition exists. If the multiframe framer checks more than fifteen multiframe bit (X-bits, P-
bits, and M-bits) positions without identifying the multiframe boundary, the multiframe framer times out, and forces
the subframe framer back into the load state. Refer to
Figure 10-40 for the multiframe framer state diagram.
10.10.4.1.2 Receive DS3 Performance Monitoring
Performance monitoring checks the DS3 frame for alarm conditions and errors. The alarm conditions detected are
OOMF, OOF, SEF, LOF, COFA, LOS, AIS, Idle, RUA1, and RDI. The errors accumulated are framing, P-bit parity,
C-bit parity (C-bit format only), and Far-End Block Error (FEBE) (C-bit format only) errors.
An Out Of MultiFrame (OOMF) condition is declared when a multiframe alignment bit (M-bit) error has been
detected in two or more of the last four consecutive DS3 frames, or when a manual resynchronization is requested.
An OOMF condition is terminated when no M-bit errors have been detected in the last four consecutive DS3
frames, or when the DS3 framer updates the data path frame counters. Refer to
Figure 10-40 for the multiframe
framer state diagram.