CHAPTER 23 INSTRUCTION SET
User’s Manual U14701EJ3V0UD
23.1 Conventions
23.1.1 Operand identifiers and specification methods
Operands are written in “Operand” column of each instruction in accordance with the specification method of the
instruction operand identifier (refer to the assembler specifications for details). When there are two or more methods,
select one of them. Alphabetic letters in capitals and symbols, #, !, $, and [ ] are key words and must be written as
they are. Each symbol has the following meaning.
#:
!:
$:
[ ]: Indirect address specification
Immediate data specification
Absolute address specification
Relative address specification
In the case of immediate data, describe an appropriate numeric value or a label. When using a label, be sure to
write the #, !, $, and [ ] symbols.
For operand register identifiers, r and rp, either function names (X, A, C, etc.) or absolute names (names in
parentheses in the table below, R0, R1, R2, etc.) can be used for specification.
Table 23-1. Operand Identifiers and Specification Methods
Identifier
Specification Method
r
rp
sfr
sfrp
X (R0), A (R1), C (R2), B (R3), E (R4), D (R5), L (R6), H (R7)
AX (RP0), BC (RP1), DE (RP2), HL (RP3)
Special function register symbol
Note
Special function register symbol (16-bit manipulatable register even addresses only)
Note
saddr
saddrp
FE20H to FF1FH Immediate data or labels
FE20H to FF1FH Immediate data or labels (even address only)
addr16
0000H to FFFFH Immediate data or labels
(only even addresses for 16-bit data transfer instructions)
0800H to 0FFFH Immediate data or labels
0040H to 007FH Immediate data or labels (even address only)
addr11
addr5
word
byte
bit
16-bit immediate data or label
8-bit immediate data or label
3-bit immediate data or label
RBn
RB0 to RB3
Note
Addresses from FFD0H to FFDFH cannot be accessed with these operands.
Remark
For special function register symbols, refer to
Table 3-4 Special Function Register List
.