XRT84L38
194
OCTAL T1/E1/J1 FRAMER
REV. 1.0.1
4.1.3.1
When the Transmit Multiplex Enable bit is set to zero and the Transmit Interface Mode Select [1:0] bits are set to
01, the Transmit Back-plane interface of framer is running at a data rate of 2.048Mbit/s.
T1 Transmit Input Interface - MVIP 2.048 MHz
The interface consists of the following pins:
Data input (TxSer_n)
Transmit Serial Clock Input signal (TxSerClk_n)
Transmit Single-frame Synchronization Input signal (TxSync_n)
Transmit Input Clock (TxInClk_n)
Transmit Time-slot Indication clock (TxTSClk_n)
Transmit Time Slot indicator bits (TxTSb[4:0]_n)
The Transmit Back-plane interface is accepting data through TxSer_n at an E1 equivalent data rate of 2.048Mbit/
s. The local Terminal Equipment supplies a free-running 2.048MHz clock to the Transmit Input Clock pin of the
framer. The local Terminal Equipment also provides synchronized payload data at rising edge of the clock. The
Transmit High-speed Back-plane Interface of the framer then latches incoming serial data at falling edge of the
Transmit Input Clock. The local Terminal Equipment should pump in data grouped in 256-bit frame 8000 times
every second. Each frame consists of thirty-two octets as in E1. The local Terminal Equipment maps a 193-bit T1
frame into this 256-bit format as described below:
1.
The Framing (F-bit) is mapped into MSB of the first E1 Time-slot. The local Terminal Equipment will stuff
the rest seven bits of the first octet with "don't care" bits that would be ignored by the framer.
2.
Payload data of T1 Time-slot 0, 1 and 2 are mapped into E1 Time-slot 1, 2 and 3.
3.
The local Terminal Equipment will stuff E1 Time-slot 4 with eight "don't care" bits that would be ignored by
the framer.
4.
Following the same rules of Step 2 and 3, the local Terminal Equipment maps every three time-slots of T1
payload data into four E1 time-slots.
The mapping of T1 frame into E1 framing format is shown in the table below.
The Transmit Single-frame Synchronization input signal (TxSync_n) should pulse HIGH at the beginning (F-bit
position) of the 256-bit frame indicating start of the frame. By sampling the HIGH pulse on the Transmit Single-
frame Synchronization signal, the framer can position the beginning of a DS1 frame. It is responsibility of the local
Terminal Equipment to align the Transmit Single-frame Synchronization signal with serial data stream going into
the framer.
Inside the framer, all the "don't care" bits will be stripped away. The framing bits, signaling and payload data are
then processed by the framer and send to LIU interface. The local Terminal Equipment provides a free-running
T
ABLE
39: T
HE
MAPPING
OF
T1
FRAME
INTO
E1
FRAMING
FORMAT
T1
F-Bit
TS0
TS1
TS2
Don't Care Bits
TS3
TS4
TS5
E1
TS0
TS1
TS2
TS3
TS4
TS5
TS6
TS7
T1
Don't Care Bits
TS6
TS7
TS8
Don't Care Bits
TS9
TS10
TS11
E1
TS8
TS9
TS10
TS11
TS12
TS13
TS14
TS15
T1
Don't Care Bits
TS12
TS13
TS14
Don't Care Bits
TS15
TS16
TS17
E1
TS16
TS17
TS18
TS19
TS20
TS21
TS22
TS23
T1
Don't Care Bits
TS18
TS19
TS20
Don't Care Bits
TS21
TS22
TS23
E1
TS24
TS25
TS26
TS27
TS28
TS29
TS30
TS31