GF9330 Data Sheet
27 of 42
Proprietary and Confidential
18283 - 4
June 2004
8
5:0
STANDARD
CONFIGURATION
REGISTERS
UC
Must be set to default value.
100100
15:6
DETAIL_ENH[9:0]
UC
Defines the detail enhancement configuration. The upper five
bits of this word adjust the high frequency detail in the image.
The lower 5-bits control the resolution or granularity. A higher
value represents more detail with higher granularity.
Detail Enhancement = Y / X
Y = DETAIL_ENH[9:5]
X = DETAIL_ENH[4:0]
0 <= Y <= 31
X = 1 | 2 | 4 | 8 | 16
00000000
01
9
11:0
CROP_H_LINE_SIZE
[11:0]
UC
Specifies the length of the line to output, following the cropped
pixels on the left side of the line.
00000000
0000
10
11:0
CROP_H_CROP_SIZE
[11:0]
UC
Specifies the number of active pixels to blank at the beginning
of each line.
00000000
0000
11
11:0
CROP_V_FRAME_
SIZE[11:0]
UC
Specifies the number of lines to output, following the cropped
lines at the top of the frame (or field).
00000000
0000
12
11:0
CROP_V_CROP_
SIZE[11:0]
UC
Specifies the number of active lines to blank at the beginning of
each frame.
00000000
0000
14,13
2:0, 15:0
STANDARD
CONFIGURATION
REGISTERS
UC
Must be set to default value.
00080H
(128
decimal)
16,15
2:0, 15:0
MSF[18:0]
UC
Represents the number of pixels per smallest active field
divided by a scaling factor required to estimate same frame
detection. A higher value also means vertical edges will have
more effect on the detection of same frames. The equation is
as follows:
MSF = #active_pixels_per_smallest_field / 2
7
Calculated
18, 17
2:0, 15:0
DIFF3T[18:0]
UC
Represents the number of active pixels per smallest field
divided by a factor required to estimate the odd and even
pattern detection. The equation is as follows:
DIFF3T = #active_pixels_per_smallest_field /2
7
Calculated
19
7:0
V_BLANK_SIZE_
EVEN[7:0
]
AC
Defines the number of lines that comprise the vertical blanking
interval that follows the even input field. This parameter has a
maximum value of 255.
Auto
15:8
V_BLANK_SIZE_
ODD[7:0]
AC
Defines the number of lines that comprise the vertical blanking
interval that follows the odd input field. This parameter has a
maximum value of 255.
Auto
20
10:0
ACTIVE_LINE_
FIELD[10:0]
AC
Defines the number of active lines per smallest input field.
Auto
15:12
V_BLANK_OFFSET
[3:0]
AC
For 3:2 pull-down compensation, this parameter must provide
the difference (if any) in number of input active lines per frame
and the number of output active lines per frame.
Auto
Table 3-5: Control Register Definitions (Continued)
Address
Bit
Location
Register Name
Class
Description
Default