CHAPTER 9
PIU (TOUCH PANEL INTERFACE UNIT)
User’s Manual U14579EJ2V0UM
138
9.3.5
PIUCMDREG (base address + 0x0AA)
Bit
1514
131211
10
9
8
Name
RFU
STABLEON
TPYEN1
TPYEN0
TPXEN1
TPXEN0
R/W
R
R/W
After reset
0
000
Bit
7
6
543
210
Name
TPYD1
TPYD0
TPXD1
TPXD0
ADCMD3
ADCMD2
ADCMD1
ADCMD0
R/W
After reset
0
001
111
Bit
Name
Function
15:13
RFU
Reserved. Write 0 to these bits. 0 is returned after a read.
12
STABLEON
Touch panel applied voltage stabilization time set during command scan
(STABLE(5:0) area of PIUSTBLREG register) enable
1: Retain panel voltage stabilization time
0: Ignore panel voltage stabilization time (voltage stabilization standby time = 0)
11:10
TPYEN(1:0)
TPY port output enable switching during command scan
11: TPY1 output, TPY0 output
10: TPY1 output, TPY0 OFF (Hi-Z)
01: TPY1 OFF (Hi-Z), TPY0 output
00: TPY1 OFF (Hi-Z), TPY0 OFF (Hi-Z)
9:8
TPXEN(1:0)
TPX port output enable switching during command scan
11: TPX1 output, TPX0 output
10: TPX1 output, TPX0 OFF (Hi-Z)
01: TPX1 OFF (Hi-Z), TPX0 output
00: TPX1 OFF (Hi-Z), TPX0 OFF (Hi-Z)
7:6
TPYD(1:0)
TPY output level during command scan
11: TPY1 = High, TPY0 = High
10: TPY1 = High, TPY0 = Low
01: TPY1 = Low, TPY0 = High
00: TPY1 = Low, TPY0 = Low
5:4
TPXD(1:0)
TPX output level during command scan
11: TPX1 = High, TPX0 = High
10: TPX1 = High, TPX0 = Low
01: TPX1 = Low, TPX0 = High
00: TPX1 = Low, TPX0 = Low
3:0
ADCMD(3:0)
A/D converter input port selection for command scan
1111: A/D converter standby mode request
1110: Reserved
:
0100: Reserved
0011: AUDIOIN port
0010: ADIN port
0001: ADY port
0000: ADX port
This register switches input/output and sets output level for each port during a command scanning operation.
Setting of the TPYD bit is invalid when the port output is set to OFF by the TPYEN bit.