11 16-bit Timer (T16)
11-2
EPSON
S1C17003 TECHNICAL MANUAL
11.2 16-bit Timer Operating Modes
The 16-bit timer has the following three operating modes:
1. Internal clock mode (Normal timer counting internal clock)
2. External clock mode (Functions as event counter)
3. Pulse width measurement mode (Counts external input pulse width using internal clock)
The operating mode is selected using CKSL[1:0] (D[9:8]/T16_CTLx register).
CKSL[1:0]: Input Clock and Pulse Width Count Mode Select Bits in the 16-bit Timer Ch.x Control (T16_CTLx)
Register (D[9:8]/0x4226/0x4246/0x4266)
Table 11.2.1: Operating mode selection
CKSL[1:0]
Operating mode
0x3
Reserved
0x2
Pulse width measurement mode
0x1
External clock mode
0x0
Internal clock mode
(Default: 0x0)
11.2.1 Internal Clock Mode
Internal clock mode uses the prescaler output clock as the count clock.
The timer counts down from the initial value set in the reload data register and outputs an underflow signal when
the counter underflows. The underflow signal is used to generate an interrupt and an internal serial interface clock.
The time until underflow occurs can be finely programmed by selecting the prescaler clock and initial counter
value, making it useful for serial transfer clock generation and sporadic time measurement.
Count clock selection
The count clock is selected by the DF[3:0] (D[3:0]/T16_CLKx register) from the 15 types generated by the
prescaler dividing the PCLK clock into 1/1 to 1/16 K divisions.
DF[3:0]: Timer Input Clock Select Bits in the 16-bit Timer Ch.x Input Clock Select (T16_CLKx) Register
(D[3:0]/0x4220/0x4240/0x4260)
Table 11.2.1.1: Count clock selection
DF[3:0]
Prescaler output clock
DF[3:0]
Prescaler output clock
0xf
Reserved
0x7
PCLK-1/128
0xe
PCLK-1/16384
0x6
PCLK-1/64
0xd
PCLK-1/8192
0x5
PCLK-1/32
0xc
PCLK-1/4096
0x4
PCLK-1/16
0xb
PCLK-1/2048
0x3
PCLK-1/8
0xa
PCLK-1/1024
0x2
PCLK-1/4
0x9
PCLK-1/512
0x1
PCLK-1/2
0x8
PCLK-1/256
0x0
PCLK-1/1
(Default: 0x0)
Note: The prescaler must run before operating the 16-bit timer in internal clock mode.
Make sure the 16-bit timer count is halted before changing count clock settings.
For detailed information on the prescaler control, see “9 Prescaler (PSC).”