參數(shù)資料
型號(hào): OX16C954-TQC60-B
廠商: Electronic Theatre Controls, Inc.
英文描述: High Performance Quad UART with 128-byte FIFOs Intel / Motorola Bus Interface
中文描述: UART的高性能四路128字節(jié)的FIFO英特爾/摩托羅拉總線(xiàn)接口
文件頁(yè)數(shù): 32/54頁(yè)
文件大?。?/td> 529K
代理商: OX16C954-TQC60-B
Data Sheet Revision 1.0
Page 32
OX16C954 rev B
OXFORD SEMICONDUCTOR LTD.
EFR[6]: Enable automatic RTS flow control.
logic 0
RTS flow control is disabled (default).
logic 1
RTS flow control is enabled in Enhanced mode
(i.e. EFR[4] = 1), where the RTS#pin will be
forced inactive high if the RFL reaches the
upper flow control threshold. This will be
released when the RFL drops below the lower
threshold. 650 and 950-mode drivers should
use this bit to enable RTS flow control. 750
mode drivers should use MCR[5].
EFR[7]: Enable automatic CTS flow control.
logic 0
CTS flow control is disabled (default).
logic 1
CTS flow control is enabled in Enhanced mode
(i.e. EFR[4] = 1), where the data transmssion is
prevented whenever the CTS#pin is held
inactive high. 650 and 950-mode drivers should
use this bit to enable CTS flow control. 750
mode drivers should use MCR[5].
13.2 Special Character Detection
In Enhanced mode (EFR[4]=1), when special character
detection is enabled (EFR[5]=1) and the receiver matches
received data with XOFF2, the 'received special character'
flag ASR[4] will be set and a level 5 interrupt is asserted, if
enabled by IER[5]. This flag will be cleared following a read
of ASR. The received status (i.e. parity and framng) of
special characters does not have to be valid for these
characters to be accepted as valid matches.
13.3 Automatic In-band Flow Control
When in-band receive flow control is enabled, the UART
will compare the received data with XOFF1 or XOFF2
characters to detect an XOFF condition. When this occurs,
the UART will disable transmssion as soon as any current
character transmssion is complete. Status bits ISR[4] and
ASR[0] will be set. A level 5 interrupt will occur (if enabled
by IER[5]). The UART will then compare all received data
with XON1 or XON2 characters to detect an XON
condition. When this occurs, the UART will re-enable
transmssion and status bits ISR[4] and ASR[0] will be
cleared.
Any valid XON/XOFF characters will not be written into the
RHR. An exception to this rule occurs if special character
detection is enabled and an XOFF2 character is received
that is a valid XOFF. In this instance, the character will be
written into the RHR.
The received status (i.e. parity and framng) of XON/XOFF
characters does not have to be valid for these characters to
be accepted as valid matches.
When the 'XON Any' flag (MCR[5]) is set, any received
character is accepted as a valid XON condition and the
transmtter will be re-enabled. The received data will be
transferred to the RHR.
When in-band transmt flow control is enabled, the RFL will
be sampled whenever the transmtter is idle (briefly,
between characters, or when the THR is empty) and an
XON/XOFF character will be inserted into the data stream
if needed. Initially, remote transmssions are enabled and
hence ASR[1] is clear. If ASR[1] is clear and the RFL has
passed the upper trigger level (i.e. is above the trigger
level), XOFF will be sent and ASR[1] will be set. If ASR[1]
is set and the RFL falls below the lower trigger level, XON
will be sent and ASR[1] will be cleared.
If transmt flow control is disabled after an XOFF has been
sent, an XON will be sent automatically.
13.4 Automatic Out-of-band Flow Control
Automatic RTS/CTS flow control is selected by different
means, depending on whether the UART is in Enhanced or
non-Enhanced mode. When in non-Enhanced mode,
MCR[5] enables both RTS and CTS flow control. When in
Enhanced mode, EFR[6] enables automatic RTS flow
control and EFR[7] enables automatic CTS flow control.
This allows software compatibility with both 16C650 and
16C750 drivers.
When automatic CTS flow control is enabled and the CTS#
input becomes active, the UART will disable transmssion
as soon as any current character transmssion is complete.
Transmssion is resumed whenever the CTS#input
becomes inactive.
When automatic RTS flow control is enabled, the RTS#pin
will be forced inactive when the RFL reaches the upper
trigger level and will return to active when the RFL falls
below the lower trigger level. The automatic RTS#flow
control is ANDed with MCR[1] and hence is only
operational when MCR[1]=1. This allows the software
driver to override the automatic flow control and disable the
remote transmtter regardless by setting MCR[1]=0 at any
time.
Automatic DTR/DSR flow control behaves in the same
manner as RTS/CTS flow control but is enabled by
ACR[3:2], regardless of whether or not the UART is in
Enhanced mode.
相關(guān)PDF資料
PDF描述
OX16CF950 LOW COST ASYNCHRONOUS 16 BIT CARD
OX2000A OCXO
OX2020A OCXO
OX2420A OCXO
OX4020A OCXO
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
OX16C95X 制造商:OXFORD 制造商全稱(chēng):OXFORD 功能描述:HIGH-PERFORMANCE UART FAMILY REFERENCE DRIVERS
OX16CB950 制造商:OXFORD 制造商全稱(chēng):OXFORD 功能描述:Intelligent UART with 3.3v PCI/Cardbus Interface
OX16CF950 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:LOW COST ASYNCHRONOUS 16 BIT CARD
OX16PCI952 制造商:OXFORD 制造商全稱(chēng):OXFORD 功能描述:Integrated High Performance Dual UARTs, Parallel Port and 5.0v PCI interface
OX16PCI952_05 制造商:OXFORD 制造商全稱(chēng):OXFORD 功能描述:Integrated High Performance Dual UARTs, Parallel Port and 5.0v PCI interface