Thermal Specifications and Design Considerations
78
Dual-Core Intel Xeon Processor 3000 Series Datasheet
With a properly designed and characterized thermal solution, it is anticipated that the
TCC would only be activated for very short periods of time when running the most
power intensive applications. The processor performance impact due to these brief
periods of TCC activation is expected to be so minor that it would be immeasurable. An
under-designed thermal solution that is not able to prevent excessive activation of the
TCC in the anticipated ambient environment may cause a noticeable performance loss,
and in some cases may result in a T
C that exceeds the specified maximum temperature
and may affect the long-term reliability of the processor. In addition, a thermal solution
that is significantly under-designed may not be capable of cooling the processor even
when the TCC is active continuously. Refer to the Dual-Core Intel Xeon Processor
3000 Series Thermal Design Guidelines for information on designing a thermal solution.
The duty cycle for the TCC, when activated by the Thermal Monitor, is factory
configured and cannot be modified. The Thermal Monitor does not require any
additional hardware, software drivers, or interrupt handling routines.
5.2.2
Thermal Monitor 2
The processor also supports an additional power reduction capability known as Thermal
Monitor 2. This mechanism provides an efficient means for limiting the processor
temperature by reducing the power consumption within the processor.
When Thermal Monitor 2 is enabled, and a high temperature situation is detected, the
Thermal Control Circuit (TCC) will be activated. The TCC causes the processor to adjust
its operating frequency (via the bus multiplier) and input voltage (via the VID signals).
This combination of reduced frequency and VID results in a reduction to the processor
power consumption.
A processor enabled for Thermal Monitor 2 includes two operating points, each
consisting of a specific operating frequency and voltage. The first operating point
represents the normal operating condition for the processor. Under this condition, the
core-frequency-to-FSB multiple used by the processor is that contained in the
appropriate MSR and the VID is that specified in Table 2-4. These parameters represent
normal system operation.
The second operating point consists of both a lower operating frequency and voltage.
When the TCC is activated, the processor automatically transitions to the new
frequency. This transition occurs very rapidly (on the order of 5 μs). During the
frequency transition, the processor is unable to service any bus requests, and
consequently, all bus traffic is blocked. Edge-triggered interrupts will be latched and
kept pending until the processor resumes operation at the new frequency.
Once the new operating frequency is engaged, the processor will transition to the new
core operating voltage by issuing a new VID code to the voltage regulator. The voltage
regulator must support dynamic VID steps to support Thermal Monitor 2. During the
voltage change, it will be necessary to transition through multiple VID codes to reach
the target operating voltage. Each step will likely be one VID table entry (see
Table 2-4). The processor continues to execute instructions during the voltage
transition. Operation at the lower voltage reduces the power consumption of the
processor.
A small amount of hysteresis has been included to prevent rapid active/inactive
transitions of the TCC when the processor temperature is near its maximum operating
temperature. Once the temperature has dropped below the maximum operating
temperature, and the hysteresis timer has expired, the operating frequency and
相關(guān)PDF資料
PDF描述
BX80562X3210SLACU 64-BIT, 266 MHz, MICROPROCESSOR, PBGA775
BX80616I5660SLBLV 64-BIT, 133 MHz, MICROPROCESSOR, PBGA1156
BXA10-48D15-S DC to DC Converter
BXA10-48S05 EMI FILTER INCLUDING ESD PROTECTION
BXA10-48S05-S 8 line low capacitance EMI filter and ESD protection
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
BX80557430SL9XN 制造商:INTEL 制造商全稱:Intel Corporation 功能描述:Intel?? Celeron?? Processor 400 Series
BX80557440 S L9XL 制造商:Intel 功能描述:MPU Celeron
BX80557E1500 制造商:Intel 功能描述:INTEL CELERON PROCESSOR E15002.2GHZ 800MHZ FSB 512KB L2
BX80557E1500 S LAQZ 制造商:Intel 功能描述:INTEL CELERON PROCESSOR FAMILY E1500, 2.2 GHZ CPU SPEED
BX80557E1600 制造商:Intel 功能描述:INTEL CELERON PROCESSOR E16002.4GHZ 800MHZ FSB 512KB L2