CHAPTER 19 RECOMMENDED SOLDERING CONDITIONS
User’s Manual U12768EJ4V1UD
463
Table 19-1. Surface Mounting Type Soldering Conditions (2/4)
(3)
PD70F3017AGC-8EU: 100-pin plastic LQFP (fine pitch) (14 × 14)
PD70F3017AYGC-8EU: 100-pin plastic LQFP (fine pitch) (14 × 14)
Soldering
Method
Soldering Conditions
Recommended
Condition
Symbol
Infrared reflow
Package peak temperature: 235°C, Time: 30 seconds max. (at 210°C or higher),
Count: Two times or less
Exposure limit: 3 days
Note (after that, prebake at 125°C for 10 hours)
IR35-103-2
VPS
Package peak temperature: 215°C, Time: 40 seconds max. (at 200°C or higher),
Count: Two times or less
Exposure limit: 3 days
Note (after that, prebake at 125°C for 10 hours)
VP15-103-2
Partial heating
Pin temperature: 350°C max., Time: 3 seconds max. (per pin row)
–
Note
After opening the dry pack, store it at 25°C or less and 65% RH or less for the allowable storage period.
Caution
Do not use different soldering methods together (except for partial heating).
(4)
PD703014AF1-×××-EA6:
121-pin plastic FBGA (12
× 12)
PD703014AYF1-×××-EA6: 121-pin plastic FBGA (12 × 12)
PD703015AF1-×××-EA6:
121-pin plastic FBGA (12
× 12)
PD703015AYF1-×××-EA6: 121-pin plastic FBGA (12 × 12)
PD703017AF1-×××-EA6:
121-pin plastic FBGA (12
× 12)
PD703017AYF1-×××-EA6: 121-pin plastic FBGA (12 × 12)
PD70F3017AF1-EA6:
121-pin plastic FBGA (12
× 12)
PD70F3017AYF1-EA6:
121-pin plastic FBGA (12
× 12)
Soldering
Method
Soldering Conditions
Recommended
Condition
Symbol
Infrared reflow
Package peak temperature: 235°C, Time: 30 seconds max. (at 210°C or higher),
Count: Two times or less,
Exposure limit: 7 days
Note (after that, prebake at 125°C for 10 hours)
IR35-107-2
VPS
Package peak temperature: 215°C, Time: 40 seconds max. (at 200°C or higher),
Count: Two times or less,
Exposure limit: 7 days
Note (after that, prebake at 125°C for 10 hours)
VP15-107-2
Note
After opening the dry pack, store it at 25°C or less and 65% RH or less for the allowable storage period.
Caution
Do not use different soldering methods together (except for partial heating).