參數(shù)資料
型號(hào): SN54ABT18502HVR
廠商: TEXAS INSTRUMENTS INC
元件分類: 總線收發(fā)器
英文描述: ABT SERIES, DUAL 9-BIT BOUNDARY SCAN REG TRANSCEIVER, TRUE OUTPUT, CQFP68
封裝: CERAMIC, QFP-68
文件頁數(shù): 29/30頁
文件大?。?/td> 451K
代理商: SN54ABT18502HVR
SN54ABT18502, SN74ABT18502
SCAN TEST DEVICES WITH
18-BIT REGISTERED BUS TRANSCEIVERS
SCBS109B – AUGUST 1992 – REVISED JUNE 1993
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
8
state diagram description (continued)
Shift-DR
Upon entry to the Shift-DR state, the data register is placed in the scan path between TDI and TDO and, on the
first falling edge of TCK, TDO goes from the high-impedance state to an active state. TDO enables to the logic
level present in the least significant bit of the selected data register.
While in the stable Shift-DR state, data is serially shifted through the selected data register on each TCK cycle.
The first shift occurs on the first rising edge of TCK after entry to the Shift-DR state (i.e., no shifting occurs during
the TCK cycle in which the TAP controller changes from Capture-DR to Shift-DR or from Exit2-DR to Shift-DR).
The last shift occurs on the rising edge of TCK upon which the TAP controller exits the Shift-DR state.
Exit1-DR, Exit2-DR
The Exit1-DR and Exit2-DR states are temporary states used to end a data register scan. It is possible to return
to the Shift-DR state from either Exit1-DR or Exit2-DR without recapturing the data register.
On the first falling edge of TCK after entry to Exit1-DR, TDO goes from the active state to the high-impedance
state.
Pause-DR
No specific function is performed in the stable Pause-DR state, in which the TAP controller can remain
indefinitely. The Pause-DR state provides the capability of suspending and resuming data register scan
operations without loss of data.
Update-DR
If the current instruction calls for the selected data register to be updated with current data, such update occurs
on the falling edge of TCK following entry to the Update-DR state.
Capture-IR
When an instruction register scan is selected, the TAP controller must pass through the Capture-IR state. In the
Capture-IR state, the instruction register captures its current status value. This capture operation occurs on the
rising edge of TCK upon which the TAP controller exits the Capture-IR state.
For the
′ABT18502, the status value loaded in the Capture-IR state is the fixed binary value 10000001.
Shift-IR
Upon entry to the Shift-IR state, the instruction register is placed in the scan path between TDI and TDO and,
on the first falling edge of TCK, TDO goes from the high-impedance state to an active state. TDO enables to
the logic level present in the least significant bit of the instruction register.
While in the stable Shift-IR state, instruction data is serially shifted through the instruction register on each TCK
cycle. The first shift occurs on the first rising edge of TCK after entry to the Shift-IR state (i.e., no shifting occurs
during the TCK cycle in which the TAP controller changes from Capture-IR to Shift-IR or from Exit2-IR to
Shift-IR). The last shift occurs on the rising edge of TCK upon which the TAP controller exits the Shift-IR state.
Exit1-IR, Exit2-IR
The Exit1-IR and Exit2-IR states are temporary states used to end an instruction register scan. It is possible to
return to the Shift-IR state from either Exit1-IR or Exit2-IR without recapturing the instruction register.
On the first falling edge of TCK after entry to Exit1-IR, TDO goes from the active state to the high-impedance
state.
相關(guān)PDF資料
PDF描述
SN54ABT2245W ABT SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, CDFP20
SN54ABT2952AFK ABT SERIES, 8-BIT REGISTERED TRANSCEIVER, TRUE OUTPUT, CQCC28
SN54ABT2952AJT ABT SERIES, 8-BIT REGISTERED TRANSCEIVER, TRUE OUTPUT, CDIP24
SN54ABT8245FK ABT SERIES, 8-BIT BOUNDARY SCAN TRANSCEIVER, TRUE OUTPUT, CQCC28
SN54ABT853FK ABT SERIES, 8-BIT TRANSCEIVER, TRUE OUTPUT, CQCC28
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
SN54ABT18504 制造商:TI 制造商全稱:Texas Instruments 功能描述:SCAN TEST DEVICES WITH 20-BIT UNIVERSAL BUS TRANSCEIVERS
SN54ABT18504_08 制造商:TI 制造商全稱:Texas Instruments 功能描述:SCAN TEST DEVICES WITH 20-BIT UNIVERSAL BUS TRANSCEIVERS
SN54ABT18504HV 制造商:TI 制造商全稱:Texas Instruments 功能描述:SCAN TEST DEVICES WITH 20-BIT UNIVERSAL BUS TRANSCEIVERS
SN54ABT18640 制造商:TI 制造商全稱:Texas Instruments 功能描述:SCAN TEST DEVICES WITH 18-BIT INVERTING BUS TRANSCEIVERS
SN54ABT18640WD 制造商:TI 制造商全稱:Texas Instruments 功能描述:SCAN TEST DEVICES WITH 18-BIT INVERTING BUS TRANSCEIVERS