參數(shù)資料
型號(hào): COM20019ILJP
廠商: STANDARD MICROSYSTEMS CORP
元件分類: 微控制器/微處理器
中文描述: 1 CHANNEL(S), 312.5K bps, LOCAL AREA NETWORK CONTROLLER, PQCC28
封裝: PLASTIC, LCC-28
文件頁數(shù): 21/65頁
文件大?。?/td> 386K
代理商: COM20019ILJP
Cost Competitive ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
Rev. 09-25-07
Page 28
SMSC COM20019I
DATASHEET
BIT
BIT NAME
SYMBOL
DESCRIPTION
2
Reconfiguration
RECON
This bit, if high, indicates that the Line Idle Timer has timed out
because the RXIN pin was idle for 656 S. The RECON bit is
cleared during a "Clear Flags" command. This bit, when set, will
cause an interrupt if the corresponding bit in the IMR is also set.
The interrupt service routine should consist of examining the
MYRECON bit of the Diagnostic Status Register to determine
whether there are consecutive reconfigurations caused by this
node.
1
Transmitter
Message
Acknowledged
TMA
This bit, if high, indicates that the packet transmitted as a result of
an "Enable Transmit from Page fnn" command has been
acknowledged. This bit should only be considered valid after the
TA bit (bit 0) is set. Broadcast messages are never
acknowledged. The TMA bit is cleared by issuing the "Enable
Transmit from Page fnn" command.
0
Transmitter
Available
TA
This bit, if high, indicates that the transmitter is available for
transmitting. This bit is set when the last byte of scheduled
packet has been transmitted out, or upon execution of a "Disable
Transmitter" command. The TA bit is cleared by issuing the
"Enable Transmit from Page fnn" command after the node next
receives the token. This bit, when set, will cause an interrupt if
the corresponding bit in the IMR is also set.
Table 6.4 - Diagnostic Status Register
BIT
BIT NAME
SYMBOL
DESCRIPTION
7
My
Reconfiguration
MY-
RECON
This bit, if high, indicates that a past reconfiguration was caused
by this node. It is set when the Lost Token Timer times out, and
should be typically read following an interrupt caused by RECON.
Refer to the Improved Diagnostics section for further detail.
6
Duplicate ID
DUPID
This bit, if high, indicates that the value in the Node ID Register
matches both Destination ID characters of the token and a
response to this token has occurred. Trailing zero's are also
verified. A logic "1" on this bit indicates a duplicate Node ID, thus
the user should write a new value into the Node ID Register. This
bit is only useful for duplicate ID detection when the device is off
line, that is, when the transmitter is disabled. When the device is
on line this bit will be set every time the device gets the token.
This bit is reset automatically upon reading the Diagnostic Status
Register. Refer to the Improved Diagnostics section for further
detail.
5
Receive
Activity
RCVACT
This bit, if high, indicates that data activity (logic "1") was
detected on the RXIN pin of the device. Refer to the Improved
Diagnostics section for further detail.
4
Token Seen
TOKEN
This bit, if high, indicates that a token has been seen on the
network, sent by a node other than this one. Refer to the
Improved Diagnostic section for further detail.
3
Excessive NAK
EXCNAK
This bit, if high, indicates that either 128 or 4 Negative
Acknowledgements have occurred in response to the Free Buffer
Enquiry. This bit is cleared upon the "POR Clear Flags"
command. Reading the Diagnostic Status Register does not
clear this bit. This bit, when set, will cause an interrupt if the
corresponding bit in the IMR is also set. Refer to the Improved
Diagnostics section for further detail.
相關(guān)PDF資料
PDF描述
CP0603A2442CSTR
CP0805A0881ESTR
CP0805A1441BSTR
CP2101-GMR
CP2101
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
COM20019I-LJP 制造商:SMSC 制造商全稱:SMSC 功能描述:Low Cost ARCNET(ANSI 878.1) Controller with 2k X 8 On-Board RAM
COM20019ILJP3V 功能描述:網(wǎng)絡(luò)控制器與處理器 IC ARCNET Contrllr RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
COM20019ILJPTR 功能描述:網(wǎng)絡(luò)控制器與處理器 IC Arcnet (ANSI 878.1) Controllr 2k x 8 Ram RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
COM20019IP 制造商:Rochester Electronics LLC 功能描述:- Bulk
COM20020 制造商:SMSC 制造商全稱:SMSC 功能描述:COM20020 3.3V ULANC Universal Local Area Network Controller with 2K x 8 On-Board RAM