XRT86L30
SINGLE T1/E1/J1 FRAMER/LIU COMBO
REV. P1.0.1
PRELIMINARY
53
T
ABLE
24: R
ECEIVE
S
IGNALING
& D
ATA
L
INK
S
ELECT
R
EGISTER
- E1 M
ODE
R
EGISTER
12 - E1 M
ODE
R
ECEIVE
S
IGNALING
& D
ATA
L
INK
S
ELECT
R
EGISTER
(RS&DLSR) H
EX
A
DDRESS
: 0
X
010C
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
7
RxSa8ENB
R/W
0
This Read/Write bit is used to specify whether or not data link information will
be transported via National Bit Sa8 (bit 7 within timeslot 0 of non-FAS frames)
0 = Sa8 does not carry data link information
1 = Sa8 carries data link information
N
OTE
:
This bit-field is valid only if the RxSIGDL[2:0] = “000” or “001”. (The
National bits have been configured to carry data link bits).
6
RxSa7ENB
R/w
0
This Read/Write bit is used to specify whether or not data link information will
be transported via National Bit Sa7 (bit 6 within timeslot 0 of non-FAS frames)
0 = Sa7 does not carry data link information
1 = Sa7 carries data link information
N
OTE
:
This bit-field is valid only if the RxSIGDL[2:0] = “000” or “001”. (The
National bits have been configured to carry data link bits).
5
RxSa6ENB
R/W
0
This Read/Write bit is used to specify whether or not data link information will
be transported via National Bit Sa6 (bit 5 within timeslot 0 of non-FAS frames)
0 = Sa6 does not carry data Link information
1 = Sa6 carries data link information
N
OTE
:
This bit-field is valid only if the RxSIGDL[2:0] = “000” or “001”. (The
National bits have been configured to carry data link bits).
4
RxSa5ENB
R/W
0
This Read/Write bit is used to specify whether or not data link information will
be transported via National Bit Sa5 (bit 4 within timeslot 0 of non-FAS frames)
0 = Sa5 does not carry data link information
1 = Sa5 carries data link information
N
OTE
:
This bit-field is valid only if the RxSIGDL[2:0] = “000” or “001”. (The
National bits have been configured to carry data link bits).
3
RxSa4ENB
R/W
0
This Read/Write bit is used to specify whether or not data link information will
be transported via National Bit Sa4 (bit 3 within timeslot 0 of non-FAS frames)
0 = Sa4 does not carry data link information
1 = Sa4 carries data link information
N
OTE
:
This bit-field is valid only if the RxSIGDL[2:0] = “000” or “001”. (If the
National bits have been configured to carry data link bits).
2
RxSIGDL(2)
R/W
0
These three Read/Write bits are used to specify the type of data that is to be
extracted via D/E channel, National Bits in timeslot 0 of the non-FAS frames,
and Timeslot 16 in the outbound frames.
D/E Channel
0xx = Fractional Output
1xx = Serial Signaling Output
National Bits (Sa4-8
)
000 = Data Link Data extracted from National bits
001 = Data Link Data extracted from National bits
010 = National bits forced to 1, not used to carry data link data
011 = None (forced to 1)
1xx = Data Link Data extracted from National bits
Timeslot 16
000 = Timeslot 16 is taken directly from PCM
001 = CAS Signaling bits A,B,C,D (per time slot)
010 = CCS Signaling bits A,B,C,D
011 = CAS Signaling bits A,B,C,D (per time slot)
1xx = Timeslot 16 is taken directly from PCM
1
RxSIGDL(1)
R/W
0
0
RxSIGDL(0)
R/W
0