38
EPSON
S1C60N13 TECHNICAL MANUAL
CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (Serial Interface)
SCTRG: Clock trigger (2E7HD3)
This is a trigger to start input/output of synchronous clock.
When "1" is written : Trigger
When "0" is written : No operation
Read-out : Always "0"
When this trigger is supplied to the serial interface activating circuit, the synchronous clock (SCLK)
input/output is started.
As a trigger condition, it is required that data writing or reading on data registers SD0–SD7 be performed
prior to writing "1" to SCTRG. (The internal circuit of the serial interface is initiated through data writ-
ing/reading on data registers SD0–SD7.)
Supply trigger only once every time the serial interface is placed in the RUN state. Refrain from
perfoming trigger input multiple times, as leads to malfunctioning.
Moreover, when the synchronous clock SCLK is external clock, start to input the external clock after the
trigger.
SIOF (R11): Serial interface status (2ECHD1)
Indicates the running status of the serial interface.
When "1" is read out : RUN status
When "0" is read out : STOP status
Writing : Invalid
The RUN status is indicated from immediatery after "1" is written to SCTRG bit through to the end of
serial data input/output.
4.7.6 Programming notes
(1) If the bit data of SE2 changes while the serial interface is in the master mode, a hazard will be output
to the SCLK (P12) terminal. If this poses a problem for the system, be sure to set the SCLK to the
external clock if the bit data of SE2 is to be changed.
(2) Be sure that read-out of the interrupt factor flag (ISIO) is done only when the serial port is in the STOP
status (SIOF = "0") and the DI status (interrupt flag = "0"). If read-out is performed while the serial
data is in the RUN status (during input or output), the data input or output will be suspended and the
initial status resumed. Read-out during the EI status (interrupt flag = "1") causes malfunctioning.
(3) When using the serial interface in the master mode, the synchronous clock uses the CPU system clock.
Accordingly, do not change the system clock (fOSC1
fOSC3) while the serial interface is operating.
(4) Perform data writing/reading to data registers SD0–SD7 only while the serial interface is halted (i.e.,
the synchronous clock is neither being input or output).
(5) As a trigger condition, it is required that data writing or reading on data registers SD0–SD7 be per-
formed prior to writing "1" to SCTRG. (The internal circuit of the serial interface is initiated through
data writing/reading on data registers SD0–SD7.) Supply trigger only once every time the serial
interface is placed in the RUN state. Moreover, when the synchronous clock SCLK is external clock,
start to input the external clock after the trigger.
(6) Be sure that writing to the interrupt mask register is done only in the DI status (interrupt flag = "0").
Writing to the interrupt mask register while in the EI status (interrupt flag = "1") may cause malfunc-
tion.
相關(guān)PDF資料
PDF描述
S1C60L16F0A0100 4-BIT, MROM, 0.032768 MHz, MICROCONTROLLER, PQFP80
S1C60N01F 4-BIT, MROM, 0.08 MHz, MICROCONTROLLER, PQFP48
S1C60N02D 4-BIT, MROM, 0.08 MHz, MICROCONTROLLER, UUC52
S1C60L02 4-BIT, MROM, 0.08 MHz, MICROCONTROLLER, PQFP60
S1C60N04D 4-BIT, MROM, 2 MHz, MICROCONTROLLER, UUC48
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
S1C60A16 制造商:EPSON 制造商全稱:EPSON 功能描述:4-bit Single Chip Microcomputer
S1C60L05 制造商:EPSON 制造商全稱:EPSON 功能描述:4-bit Single Chip Microcomputer
S1C60L08 制造商:EPSON 制造商全稱:EPSON 功能描述:4-bit Single Chip Microcomputer
S1C60L16 制造商:EPSON 制造商全稱:EPSON 功能描述:4-bit Single Chip Microcomputer
S1C60N05 制造商:EPSON 制造商全稱:EPSON 功能描述:4-bit Single Chip Microcomputer